HO60-P Datasheet, PDF (2/15 Pages) LEM – Current Transducer
HO 60 .. 250-P series
Absolute maximum ratings
Parameter
Supply voltage (not destructive)
Supply voltage (not entering non standard modes)
Primary conductor temperature
ESD rating, Human Body Model (HBM)
Symbol
UC
UC
TB
UESD
Unit
V
V
°C
kV
Value
8
6.5
120
2
Stresses above these ratings may cause permanent damage. Exposure to absolute maximum ratings for extended periods may
degrade reliability.
UL 508: Ratings and assumptions of certification
File # E189713 Volume: 2 Section: 5
Standards
●● CSA C22.2 NO. 14-10 INDUSTRIAL CONTROL EQUIPMENT - Edition 11 - Revision Date 2011/08/01
●● UL 508 STANDARD FOR INDUSTRIAL CONTROL EQUIPMENT - Edition 17 - Revision Date 2010/04/15
Ratings
Parameter
Primary involved potential
Symbol
Unit
V AC/DC
Value
600
Max surrounding air temperature
Primary current
Secondary supply voltage
Output voltage
TA
°C
105
IP
A
According to series primary
current
UC
V DC
Vout
V
5
0 to 5
Conditions of acceptability
1 - These devices have been evaluated for overvoltage category III and for use in pollution degree 2 environment.
2 - A suitable enclosure shall be provided in the end-use application.
3 - The terminals have not been evaluated for field wiring.
4 - These devices are intended to be mounted on a printed wiring board of end use equipment. The suitability of the
connections (including spacings) shall be determined in the end-use application.
5 - Primary terminals shall not be straightened since assembly of housing case depends upon bending of the terminals.
6 - Any surface of polymeric housing have not been evaluated as insulating barrier.
7 - Low voltage control circuit shall be supplied by an isolating source (such as a transformer, optical isolator,
limiting impedance or electro-mechanical relay).
10 - The jumper installed within the primary hole is only intended for fixing the sensor and not for carrying the primary current.
Marking
Only those products bearing the UR Mark should be considered to be Listed or Recognized and covered under UL's Follow-Up
Service. Always look for the Mark on the product.