06 | Keysight | U1450A/U1460A Insulation Resistance Testers - Data Sheet
U1450A/U1460A Series Comparison Chart at a glance
Industry
Display type
Basic features
Insulation test voltage range
Insulation resistance range
Earth bond resistance range
Timed, PI, DAR
Adjustable insulation test
voltages
Live circuit test inhibit
(30 V, 50 V, 75 V)
Calculate cable length by
capacitance
Automatic discharge for
capacitive circuits under test
Data management
Remote testing and report
generation1
Multimeter features
DMM display resolution
AC speciication
Measurements
DMM special features
Low Pass Filter (LPF)
Non-Contact AC Voltage
Detection (Vsense)
General speciications
IP rating, drop test
Safety protection
Operating temperature
Battery life
Warranty
U1451A
LCD
250 V, 500 V,
1,000 V
66 GΩ
60 Ω to 60 KΩ
Timed only
–
√
√
√
Industrial and Power
U1452A
U1453A
LCD
OLED
U1461A
OLED
50 V, 100 V, 250 V,
500 V, 1,000 V
260 GΩ
60 Ω to 60 KΩ
√
–
50 V, 100 V, 250 V,
500 V, 1,000 V
260 GΩ
6 Ω to 60 KΩ
√
10 V to 1.1 KV
50 V, 100 V, 250 V,
500 V, 1,000 V
260 GΩ
6 Ω to 60 KΩ
√
10 V to 1.1 KV
√
√
√
√
√
√
√
√
√
√
√
√
√
6,600 counts
Calibrated for sine
wave
AC/DC voltage, re-
sistance, continuity,
capacitance
6,600 counts
Calibrated for sine
wave
AC/DC voltage, re-
sistance, continuity,
capacitance
66,0002/
6,600 counts
True RMS
AC/DC voltage, re-
sistance, continuity,
capacitance,
diode test
66,0002/
6,600 counts
True RMS
AC/DC voltage
(V, mV), AC/DC
current (μA, mA),
resistance, continu-
ity, capacitance,
diode test, tem-
perature
–
–
–
√
–
–
–
√
IP 67, 10 ft
(3 meters)
CAT III 1000 V/
CAT IV 600 V
–20 to +55 °C
270 hours
3 years
IP 67, 10 ft
(3 meters)
CAT III 1000 V/
CAT IV 600 V
–20 to +55 °C
270 hours
3 years
IP 67, 10 ft
(3 meters)
CAT III 1000 V/
CAT IV 600 V
–40 to +55 °C
160 hours
3 years
IP 67, 10 ft
(3 meters)
CAT III 1000 V/
CAT IV 600 V
–40 to +55 °C
160 hours
3 years
Telecommunication
U1452AT
LCD
50 V, 100 V
66 GΩ
60 Ω to 60 KΩ
√
–
√
√
√
√
6,600 counts
Calibrated for sine
wave
AC/DC voltage, re-
sistance, continuity,
capacitance
–
–
IP 67, 10 ft
(3 meters)
CAT III 1000 V/
CAT IV 600 V
–20 to +55 °C
270 hours
3 years
1. Requires the Keysight Handheld Logger software for Windows PC, or the Keysight Insulation Tester app for iOS/Android smart devices
2. User selectable display resolution in MENU default is 6,600 counts