25 | Keysight | E1962B cdma2000/IS-95/AMPS Mobile Test Application - Technical Overview
CDMA analyzer (continued)
Fast device tune measurement
E1999A-202 FDT-enhanced
CDMA analyzer (continued)
Fast device tune measurement
Input frequency ranges 411 to 420 MHz
450 to 484 MHz
824 to 934 MHz
1700 to 1980 MHz
Measurement method
Allows user definition of an RF source power
output sequence simultaneously with a Tx pow-
er measurement sequence each consisting of
10 or 20 ms duration steps with a user-defined
step size. Sequence can be defined to repeat
over a number of frequencies inside of a single
frequency band. This measurement requires
a test mode in the mobile station in order to
operate. Measures the total power in a
1.23 MHz bandwidth centered on the active
reverse channel center frequency in each step
period
Measurement data
capture period
0.313 μs
Maximum input level +37 dBm/1.23 MHz peak (5 W peak)
Measurement range
–61 to +30 dBm, usable to < −69 dBm/
1.23 MHz with reduced accuracy
Measurement capture
range
Mobile station’s transmit power must be within
± 9 dB of the expected power per the ranging
configuration
Measurement accuracy
< ± 1 dB 15 to 55 °C for the fast mode, typically
< ± 0.5 dB (calibrated against average power
and within ±10 degrees of calibration tempera-
ture. Calibration must occur between 20 to
55 °C)
Measurement resolution 0.01 dBm/1.23 MHz
Measurement step
duration (time)
10ms or 20ms
Number of frequency
steps
1 to 20
Number of amplitude
steps
1 to 20 steps at each specified frequency
Maximum steps in a
sequence
Up to 20 out of the possible 40 entries in each
table
MS Tx frequency step 1 to 40 entries, with each value in MHz
table
MS Tx power step table 1 to 40 entries, with each value in dBm
MS Rx frequency step 1 to 40 entries, with each value in MHz
table
MS Rx power step table 1 to 40 entries, with each value in dBm
MS Tx frequency step 0 to 39
start index
MS Tx power step start 0 to 39
index
MS Rx frequency step 0 to 39
start index
MS Rx power step start 0 to 39
index
RF generator settling
time
< 5.7 ms to be within ± 0.1 dB of the final value
RF generator modulation Typically < 3.1%
accuracy
RF generator level
accuracy
Same as listed under 1xEV-DO RF generator
specifications
Concurrency capabilities None
Calibrate function
Calibrates all measurement functions