English
Language : 

FY0H104ZF_16 Datasheet, PDF (12/13 Pages) Kemet Corporation – Supercapacitors FY Series
Supercapacitors – FY Series
Notes on Using Supercapacitors or Electric Double-Layer Capacitors (EDLCs) cont’d
2. Mounting
2.1 Mounting onto a reflow furnace
Except for the FC series, it is not possible to mount this capacitor onto an IR / VPS reflow furnace. Do not immerse the
capacitor into a soldering dip tank.
2.2 Flow soldering conditions
See Recommended Reflow Curves in Section – Precautions for Use
2.3 Installation using a soldering iron
Care must be taken to prevent the soldering iron from touching other parts when soldering. Keep the tip of the soldering
iron under 400ºC and soldering time to within 3 seconds. Always make sure that the temperature of the tip is controlled.
Internal capacitor resistance is likely to increase if the terminals are overheated.
2.4 Lead terminal processing
Do not attempt to bend or polish the capacitor terminals with sand paper, etc. Soldering may not be possible if the
metallic plating is removed from the top of the terminals.
2.5 Cleaning, Coating, and Potting
Except for the FM series, cleaning, coating and potting must not be carried out. Consult KEMET if this type of procedure
is necessary. Terminals should be dried at less than the maximum operating temperature after cleaning.
3. Storage
3.1 Temperature and humidity
Make sure that the supercapacitor is stored according to the following conditions: Temperature: 5 – 35ºC (Standard
25ºC), Humidity: 20 – 70% (Standard: 50%). Do not allow the build up of condensation through sudden temperature
change.
3.2 Environment conditions
Make sure there are no corrosive gasses such as sulfur dioxide, as penetration of the lead terminals is possible. Always
store this item in an area with low dust and dirt levels. Make sure that the packaging will not be deformed through heavy
loading, movement and/or knocks. Keep out of direct sunlight and away from radiation, static electricity and magnetic
fields.
3.3 Maximum storage period
This item may be stored up to one year from the date of delivery if stored at the conditions stated above.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com
S6015_FY • 10/6/2016 12