English
Language : 

CPC7695 Datasheet, PDF (8/25 Pages) Clare, Inc. – Line Card Access Switch
INTEGRATED CIRCUITS DIVISION
CPC7695
1.6.4 TESTout Switches: SW5 and SW6
Parameter
Test Conditions
Symbol Minimum Typical Maximum
Unit
VSW5 (differential) = TLINE to TTESTOUT
VSW6 (differential) = RLINE to RTESTOUT
All-Off state.
+25°C,
VSW (differential) = -320V to GND
0.1
Off-State
VSW (differential) = +260V to -60V
Leakage Current
+85°C
VSW (differential) = -330V to GND
ISW
-
0.3
1
A
VSW (differential) = +260V to -60V
-40°C
VSW (differential) = -310V to GND
0.1
VSW (differential) = +250V to -60V
ISW (on) = ±10mA, ±40mA
On-Resistance
+25°C
+85°C
-40°C
RON
-
35
-
50
70

26
-
VSW (on) = ±10V
DC current limit
+25°C
+85°C
-40°C
-
140
-
ISW
80
100
-
mA
-
210
250
Dynamic current limit
(t 0.5 s)
Test out switches on, all other switches
off. Apply ±1kV, 10x1000s pulse with
appropriate protection in place.
ISW
-
2.5
-
A
VSW5 (TTESTout, TLINE)
VSW6 (RTESTout, RLINE)
Logic input to switch Logic inputs = GND
output isolation
+25°C, VSW = ±320V
0.1
+85°C, VSW = ±330V
ISW
-
0.3
1
A
-40°C, VSW = ±310V
0.1
100VPP Square Wave, 100Hz
Transient Immunity
(Not production tested - limits are
dV/dt
1500
2100
-
V/s
guaranteed by design and quality
control sampling audits.)
8
www.ixysic.com
R01