English
Language : 

CPC7695 Datasheet, PDF (13/25 Pages) Clare, Inc. – Line Card Access Switch
INTEGRATED CIRCUITS DIVISION
CPC7695
1.8 Voltage and Power Specifications
Parameter
Test Conditions
Symbol Minimum Typical Maximum
Unit
Voltage Requirements
VDD
-
VDD
4.5
5.0
5.5
V
VBAT1
-
VBAT
-19
-48
-72
V
1VBAT is used only for internal protection circuitry. If VBAT rises above -10V, the device will enter the All-Off state and will remain in the All-Off state until the battery
drops below -15V
Power Specifications
VDD = 5V, VBAT = -48V, VIH = 2.4V,
Power consumption
VIL = 0.4V, Measure IDD and IBAT
Talk and All-Off States
P
All other states
4.7
10.5
mW
-
5.2
10.5
mW
VDD = 5V, VBAT = -48V, VIH = 2.4V,
VDD current
VIL = 0.4V
Talk and All-Off states
All other states
0.9
2.0
IDD
-
mA
1.0
2.0
VBAT
current in
any
state
VDD = 5V, VBAT
VIL = 0.4V
=
-48V,
VIH
=
2.4V,
IBAT
-
4
10
A
R01
www.ixysic.com
13