English
Language : 

CPC7695 Datasheet, PDF (14/25 Pages) Clare, Inc. – Line Card Access Switch
INTEGRATED CIRCUITS DIVISION
CPC7695
1.9 Protection Circuitry Electrical Specifications
Parameter
Conditions
Symbol Minimum Typical Maximum
Unit
Protection Diode Bridge
Forward Voltage drop,
continuous current
(50/60 Hz)
Apply ± DC current limit of break
switches
VF
2.8
3.5
-
V
Forward Voltage drop, Apply ± dynamic current limit of break
surge current
switches
5
-
Protection SCR (CPC7695xA and CPC7695xC)
Surge current
-
-
-
-
*
A
Trigger current:
SCR activates, +25°C
Current into VBAT pin. SCR activates, +85°C
150
ITRIG
-
80
-
mA
Hold current: Current SCR remains active, +25°C
through protection SCR SCR remains active, +85°C
-
220
IHOLD
110
145
-
mA
Gate trigger voltage IGATE = ITRIGGER§
VTBAT or
VRBAT
VBAT -4
-
VBAT -2
V
Reverse leakage current VBAT = -48V
IVBAT
-
-
1.0
A
On-state voltage
0.5A, t = 0.5 s
2.0A, t = 0.5 s
VTBAT or
VRBAT
-
-3
-5
-
V
Temperature Shutdown Specifications
Shutdown activation
temperature
Not production tested - limits are
TTSD_on
110
125
150
°C
guaranteed by design and Quality
Shutdown circuit
hysteresis
Control sampling audits.
TTSD_off
10
-
25
°C
*Passes GR1089 and ITU-T K.20 with appropriate secondary protection in place.
§VBAT must be capable of sourcing ITRIGGER for the internal SCR to activate.
14
www.ixysic.com
R01