CPC75282 Datasheet, PDF (5/19 Pages) Clare, Inc. – Line Card Access Switch | |||
|
◁ |
INTEGRATED CIRCUITS DIVISION
1.7 Switch Specifications
PRELIMINARY
1.7.1 Break Switches, SW1 and SW2
Parameter
Test Conditions
Symbol
VSW1 (differential) = TLINE to TBAT
VSW2 (differential) = RLINE to RBAT
All-Off state.
+25ï°C,
VSW (differential) = -320V to gnd
Off-State
VSW (differential) = +260V to -60V
Leakage Current
+85ï° C,
VSW (differential) = -330V to gnd
ISW
VSW (differential) = +270V to -60V
-40ï°C,
VSW (differential) = -310V to gnd
VSW (differential) = +250V to -60V
ISW(on) = ±10mA, ±40mA,
RBAT and TBAT = -2V
On Resistance
+25ï°C
+85ï°C
RON
-40ï°C
On Resistance
Matching
Per SW1 & SW2 On Resistance test
conditions.
ïRON
ON-State Voltage 1
Maximum Differential Voltage (Vmax)
Foldback Voltage Breakpoint 1 (V1)
ïVON
Foldback Voltage Breakpoint 2 (V2)
VSW (on) = ±10V, +25ï°C
DC current limit 1 (ILIM1) VSW (on) = ±10V, +85ï°C
ISW
VSW (on) = ±10V, -40ï°C
DC current limit 2 (ILIM2)
ISW
Dynamic current limit
(t = <0.5 ïs)
Break switches on, all other switches
off. Apply ±1 kV 10x1000 ïs pulse with
appropriate protection in place.
ISW
+25ï° C, OFFx = 0,
VSW (TLINE, RLINE) = ±320V
Logic Input to Switch +85ï° C, OFFx = 0,
Output Isolation
VSW (TLINE, RLINE) = ±330V
ISW
-40ï° C, OFFx = 0,
VSW (TLINE, RLINE) = ±310V
Transient Immunity 2
dV/dt
1 Choice of secondary protector should ensure this rating is not exceeded.
2 Applied voltage is 100VP-P square wave at 100Hz.
Minimum
-
-
-
-
60
V1 + 0.5
-
80
-
1
-
-
-
-
1500
R00E
PRELIMINARY
Typical
-
14.5
-
10.5
0.02
-
-
-
300
-
2.5
-
-
-
2100
CPC75282
Maximum
Unit
1
ïA
-
31
ï
-
1.0
ï
320
-
V
-
mA
425
-
-
A
1
ïA
-
V/ïs
5
|
▷ |