English
Language : 

CPC75282 Datasheet, PDF (10/19 Pages) Clare, Inc. – Line Card Access Switch
INTEGRATED CIRCUITS DIVISION
PRELIMINARY
CPC75282
1.9 Voltage and Power Specifications
Parameter
Test Conditions
Symbol Minimum Typical Maximum
Unit
Voltage Requirements
VDD
-
VDD
4.75
5.0
5.25
V
VBAT1
-
VBAT
-19
-48
-72
V
1VBAT is used only for internal protection circuitry. If VBAT rises above-10 V, the device will enter the all-off state and will remain in the all-off
state until the battery drops below approximately -15V.
Power Specifications
VDD = 5V, VBAT = -48V, VIH = 2.4V,
VIL = 0.4V, Measure IDD and IBAT
Power consumption Idle/Talk State
-
-
15 3
mW
All-Off State 2
P
-
-
7.5 3
Ringing or Test Access State
-
-
20 3
VDD = 5V, VBAT = -48V, VIH = 2.4V,
VIL = 0.4V
VDD Current
Idle/Talk State
All-Off State
-
1.6 3
3.0
mA
IDD
-
0.75 3
1.5
Ringing or Test Access State
-
1.8/1.5 3
4.0
VBAT Current
VDD = 5V, VBAT = -48V, VIH = 2.4V, VIL =
0.4V, All States
IBAT
-
4
10
A
2 Controlled via OFFx pins.
3 Combined power or current of both channels, both channels in the same state. Typical values from simulation.
1.10 Protection Circuitry Electrical Specifications
Parameter
Conditions
Symbol Minimum Typical Maximum
Unit
Protection Diode Bridge
Forward Voltage drop,
continuous current
(50/60 Hz)
Apply ± DC current limit of break
switches
VF
-
2.1
3.0
V
Forward Voltage drop, Apply ± dynamic current limit of break
surge current
switches
VF
-
5
-
Temperature Shutdown Specifications 1
Shutdown activation
temperature
Not production tested - limits are
TTSD_on
110
125
150
C
guaranteed by design and Quality
Shutdown circuit
hysteresis
Control sampling audits.
TTSD_off
10
-
25
C
Loss of Battery Detector Threshold
Loss of Battery
Resumption of Battery
-19
-10
-5
V
=19
-15
-5
1 Temperature shutdown flag (TSDx) will be high during normal operation and low during temperature shutdown state.
10
PRELIMINARY
R00E