English
Language : 

CPC75282 Datasheet, PDF (4/19 Pages) Clare, Inc. – Line Card Access Switch
INTEGRATED CIRCUITS DIVISION
PRELIMINARY
CPC75282
1.4 Absolute Maximum Ratings
1.5 ESD Rating
Parameter
Minimum Maximum Unit
+5V power supply (VDD)
-0.3
7
V
Battery Supply
-
-85
V
DGND to FGND Separation
-5
+5
V
Logic input voltage
-0.3 VDD + 0.3 V
Logic input to switch output
isolation
-
320
V
Switch open-contact
isolation (SW1, SW2, SW3, -
320
V
SW5, SW6)
Switch open-contact
Isolation (SW4)
-
465
V
Operating relative humidity
5
95
%
Operating temperature
-40
+110
C
Storage temperature
-40
+150
C
Absolute maximum electrical ratings are at 25C.
ESD Rating (Human Body Model)
1000V
1.6 General Conditions
Unless otherwise specified, minimum and maximum
values are production testing requirements. Typical
values are characteristic of the device and are the
result of engineering evaluations. They are provided
for information purposes only and are not part of the
testing requirements.
Specifications cover the operating temperature range
TA = -40C to +85C. Also, unless otherwise specified,
all testing is performed with VDD = 5VDC, logic low
input voltage is 0VDC and logic high voltage is 5VDC.
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
4
PRELIMINARY
R00E