IS61WV10248EDBLL Datasheet, PDF (7/18 Pages) Integrated Silicon Solution, Inc – TTL compatible inputs and outputs | |||
|
◁ |
IS61WV10248EDBLL
IS64WV10248EDBLL
READ CYCLE SWITCHING CHARACTERISTICS(1) (Over Operating Range)
-8
-10
Symbol Parameter Min. Max.
Min. Max. Unit
trc
Read Cycle Time
8â
10 â
ns
taa
Address Access Time
â8
â 10
ns
toha
Output Hold Time
2.5 â
2.5 â
ns
tace
CE Access Time
â8
â 10
ns
tdoe
OE Access Time
â 5.5
â 6.5
ns
thzoe(2) OE to High-Z Output
â3
â4
ns
tlzoe(2)
OE to Low-Z Output
0â
0â
ns
thzce(2
CE to High-Z Output
03
04
ns
tlzce(2)
CE to Low-Z Output
3â
3â
ns
tpu
Power Up Time
0â
0â
ns
tpd
Power Down Time
â8
â 10
ns
Notes:
1.â Test conditions and output loading conditions are specified in the AC Test Conditions and AC Test Loads (Figure 1).
2.â Tested with the load in Figure 2.Transition is measured ±500 mV from steady-state voltage.
Integrated Silicon Solution, Inc. â www.issi.com
7
Rev.âA
02/20/2013
|
▷ |