IS80LV52 Datasheet, PDF (15/48 Pages) Integrated Silicon Solution, Inc – CMOS SINGLE CHIP LOW VOLTAGE 8-BIT MICROCONTROLLER
IS80LV52
IS80LV32
ISSI ®
TIMER/COUNTERS
The IS80LV52/32 has three 16-bit Timer/Counter registers:
Timer 0, Timer 1, and in addition Timer 2. All three can be
configured to operate either as Timers or event Counters.
As a Timer, the register is incremented every machine
cycle. Thus, the register counts machine cycles. Since a
machine cycle consists of 12 oscillator periods, the count
rate is 1/12 of the oscillator frequency.
As a Counter, the register is incremented in response to
a 1-to-0 transition at its corresponding external input pin,
T0, T1, and T2. The external input is sampled during S5P2
of every machine cycle. When the samples show a high
in one cycle and a low in the next cycle, the count is
incremented. The new count value appears in the register
during S3P1 of the cycle following the one in which the
transition was detected. Since two machine cycles (24
oscillator periods) are required to recognize a 1-to-0
transition, the maximum count rate is 1/24 of the oscillator
frequency. There are no restrictions on the duty cycle of
the external input signal, but it should be held for at least
one full machine cycle to ensure that a given level is
sampled at least once before it changes.
In addition to the Timer or Counter functions, Timer 0 and
Timer 1 have four operating modes: (13-bit timer, 16-bit
timer, 8-bit auto-reload, split timer). Timer 2 in the
IS80LV52/32 has three modes of operation: Capture,
Auto-Reoload, and Baud Rate Generator.
Timer 0 and Timer 1
Timer/Counters 0 and 1 are present in both the IS80LV51/
31 and IS80LV52/32. The Timer or Counter function is
selected by control bits C/T in the Special Function
Regiser TMOD. These two Timer/Counters have four
operating modes, which are selected by bit pairs (M1, M0)
in TMOD. Modes 0, 1, and 2 are the same for both Timer/
Counters, but Mode 3 is different. The four modes are
described in the following sections.
Mode 0:
Both Timers in Mode 0 are 8-bit Counters with a divide-by-
32 prescaler. Figure 8 shows the Mode 0 operation as it
applies to Timer 1.
In this mode, the Timer register is configured as a 13-bit
register. As the count rolls over from all 1s to all 0s, it sets
the Timer interrupt flag TF1. The counted input is enabled
to the Timer when TR1 = 1 and either GATE = 0 or INT1
= 1. Setting GATE = 1 allows the Timer to be controlled by
external input INT1, to facilitate pulse width measurements.
TR1 is a control bit in the Special Function Register
TCON. Gate is in TMOD.
The 13-bit register consists of all eight bits of TH1 and the
lower five bits of TL1. The upper three bits of TL1 are
indeterminate and should be ignored. Setting the run flag
(TR1) does not clear the registers.
Mode 0 operation is the same for Timer 0 as for Timer 1,
except that TR0, TF0 and INT0 replace the corresponding
Timer 1 signals in Figure 8. There are two different GATE
bits, one for Timer 1 (TMOD.7) and one for Timer 0
(TMOD.3).
OSC
(XTAL2)
OSC
ONE MACHINE
CYCLE
ONE MACHINE
CYCLE
S1 S2 S3 S4 S5 S6 S1 S2 S3 S4 S5
P1 P2 P1 P2 P1 P2 P1 P2 P1 P2 P1 P2 P1 P2 P1 P2 P1 P2 P1 P2 P1 P2
S6
P1 P2
S1
P1 P2
DIVIDE 12
C/T = 0
T1 PIN
GATE
C/T = 1
TR1
TL1
TH1
(5 BITS) (8 BITS)
CONTROL
TF1
INTERRUPT
INT1 PIN
Figure 8. Timer/Counter 1 Mode 0: 13-Bit Counter
TIMER
TL1
TH1
TF1
CLOCK
(8 BITS) (8 BITS)
OVERFLOW
FLAG
Figure 9. Timer/Counter 1 Mode 1: 16-Bit Counter