Fault Reporting and Programmable Fault Clear Timer
The AUIRS2336S provides an integrated fault reporting output and an adjustable fault clear timer. There are two
situations that would cause the HVIC to report a fault via the FAULT pin. The first is an undervoltage condition of
VCC and the second is if the ITRIP pin recognizes a fault. Once the fault condition occurs, the FAULT pin is internally
pulled to VSS. The fault clear timer is activated only if ITRIP pin recognizes a fault: in this case the fault output stays
in the low state until the fault condition has been removed and the fault clear timer expires; once the fault clear timer
expires, the voltage on the FAULT pin will return to VCC.
The length of the fault clear time period (tFLTCLR) is determined by exponential charging characteristics of the
capacitor where the time constant is set by RRCIN and CRCIN. In Figure 12 where we see that a fault condition has
occurred (UVLO or ITRIP), RCIN and FAULT are pulled to VSS, and once the fault has been removed, the fault clear
timer begins. Figure 13 shows that RRCIN is connected between the VCC and the RCIN pin, while CRCIN is placed
between the RCIN and VSS pins.
Figure 12: RCIN and FAULT pin waveforms
Figure 13: Programming the fault clear timer
The design guidelines for this network are shown in Table 3.
CRCIN
RRCIN
≤1 nF
Ceramic
0.5 MΩ to 2 MΩ
>> RON,RCIN
Table 3: Design guidelines
The length of the fault clear time period can be determined by using the formula below.
vC(t) = Vf(1-e-t/RC)
tFLTCLR = -(RRCINCRCIN)ln(1-VRCIN,TH/VCC)