English
Language : 

ISL71590SEH Datasheet, PDF (9/16 Pages) Intersil Corporation – Radiation Hardened
ISL71590SEH
Trimming Out Errors
IDEAL
ACTUAL
(GREATLY
EXAGGERATED)
+Vs
+
T
-
~100Ω
950Ω
VOUT
Adjust R to calibrate out error
for any single temp point
T (K)
FIGURE 20. TRIMMING OUT ERRORS
FIGURE 21. SLOPE TRIMMING
IDEAL
ACTUAL
TRIMMED
T (K)
FIGURE 22. EFFECT OF SLOPE TRIM
+10v
35.7kΩ
R1 2kΩ
R1 = OFFSET
R2 = SLOPE
+
T
ISL71590SEH -
97.6kΩ
+-
R2 5kΩ
VOUT = 100mV/°C
V-
FIGURE 23. SLOPE AND OFFSET TRIMMING
T (K)
FIGURE 24. UNTRIMMED
Submit Document Feedback
9
T (K)
FIGURE 25. TRIM ONE: OFFSET
June 3, 2016
FN8376.2