Electrical Specifications Refer to “Block Diagram” on page 4 and Typical Application Schematics on page 5. Operating Conditions
Unless Otherwise Noted: VIN = 12V, or VCC = 4.5V, TA = -40°C to +105°C. Typicals are at TA = +25°C. Boldface limits apply across the operating
temperature range, -40°C to +105°C. (Continued)
PARAMETER
SYMBOL
TEST CONDITIONS
MIN
MAX
(Note 7) TYP (Note 7) UNITS
Undervoltage Falling Trip Point
Undervoltage Falling Hysteresis
PGOOD Rising Delay
PGOOD Leakage Current
PGOOD Low Voltage
OVERCURRENT PROTECTION
VFB/VREF Percentage of reference point
VFB/VUVTRIP Percentage above UV trip point
tPGOODR_DELAY fOSC = 500kHz
PGOOD HIGH, VPGOOD = 4.5V
VPGOOD
PGOOD LOW, IPGOOD = 0.2mA
84 90 96
%
3
%
128
cycles
10
nA
0.10
V
Default Cycle-by-cycle Current Limit Threshold
Hiccup Current Limit Threshold
OVERVOLTAGE PROTECTION
IOC_1
IOC_2
ILIMIT = GND or VCC or Floating
Hiccup, IOC_2/IOC_1
3
3.6 4.2
A
115
%
OV 120% Trip Point
Active in and after soft-start
Percentage of Reference Point
LG = UG = LOW
120
%
OV 120% Release Point
Active in and after soft-start
Percentage of Reference Point
102.5
%
OV 110% Trip Point
Active after soft-start done
Percentage of Reference Point
LG = UG = LOW
110
%
OV 110% Release Point
Active after soft-start done.
Percentage of Reference Point
102.5
%
OVER-TEMPERATURE PROTECTION
Over-temperature Trip Point
160
°C
Over-temperature Recovery Threshold
140
°C
NOTES:
6. Wire bonds included.
7. Parameters with MIN and/or MAX limits are 100% tested at +25°C, unless otherwise specified. Temperature limits established by characterization
and are not production tested.
Submit Document Feedback
8
FN8618.2
March 25, 2015