ISL23325 Datasheet, PDF (8/20 Pages) Intersil Corporation – Dual, 256-Tap, Low Voltage Digitally Controlled Potentiometer (XDCP™)
ISL23325
Serial Interface Specification For SCL, SDA, A0, A1, A2 unless otherwise noted. (Continued)
SYMBOL
PARAMETER
TEST CONDITIONS
MIN
(Note 20)
TYP
(Note 8)
MAX
(Note 20)
UNITS
tHD:DAT Input Data Hold Time
From SCL falling edge crossing
0
ns
70% of VLOGIC to SDA entering
the 30% to 70% of VLOGIC
window
tSU:STO
tHD:STO
tDH
tR
tF
Cb
STOP Condition Set-up Time
From SCL rising edge crossing
600
70% of VLOGIC, to SDA rising
edge crossing 30% of VLOGIC
STOP Condition Hold Time for Read From SDA rising edge to SCL
or Write
falling edge; both crossing
70% of VLOGIC
1300
Output Data Hold Time
From SCL falling edge crossing
0
30% of VLOGIC, until SDA
enters the 30% to 70% of
VLOGIC window.
IOL = 3mA, VLOGIC > 2V.
IOL = 0.5mA, VLOGIC < 2V
SDA and SCL Rise Time
From 30% to 70% of VLOGIC 20 + 0.1 x Cb
SDA and SCL Fall Time
From 70% to 30% of VLOGIC 20 + 0.1 x Cb
Capacitive Loading of SDA or SCL Total on-chip and off-chip
10
ns
ns
ns
250
ns
250
ns
400
pF
tSU:A
A2, A1, A0 Setup Time
Before START condition
600
ns
tHD:A
A2, A1, A0 Hold Time
After STOP condition
600
ns
NOTES:
8. Typical values are for TA = +25°C and 3.3V supply voltages.
9. LSB = [V(RW)255 – V(RW)0]/255. V(RW)255 and V(RW)0 are V(RW) for the DCP register set to FF hex and 00 hex respectively. LSB is the incremental
voltage when changing from one tap to an adjacent tap.
10. ZS error = V(RW)0/LSB.
11. FS error = [V(RW)255 – VCC]/LSB.
12. DNL = [V(RW)i – V(RW)i-1]/LSB-1, for i = 1 to 255. i is the DCP register setting.
13. INL = [V(RW)i – i • LSB – V(RW)0]/LSB for i = 1 to 255
14.
TCV
=
M------a----x---(--V----(--R-----W-----)--i--)----–----M-----i--n----(---V---(---R----W------)--i--)
V ( R Wi ( + 25 °C ) )
×
------1----0----6-------
+ 165 °C
For i = 16 to 255 decimal, T = -40°C to +125°C. Max( ) is the maximum value of the wiper voltage
and Min( ) is the minimum value of the wiper voltage over the temperature range.
15. MI = |RW255 – RW0|/255. MI is a minimum increment. RW255 and RW0 are the measured resistances for the DCP register set to FF hex and 00
hex respectively.
16. Roffset = RW0/MI, when measuring between RW and RL.
Roffset = RW255/MI, when measuring between RW and RH.
17. RDNL = (RWi – RWi-1)/MI -1, for i = 16 to 255.
18. RINL = [RWi – (MI • i) – RW0]/MI, for i = 16 to 255.
19.
TCR
=
[---M-----a----x---(--R-----i--)---–-----M-----i--n----(--R----i--)---]
R i ( + 25 °C )
×
------1----0----6-------
+ 165 °C
for i = 16 to 255, T = -40°C to +125°C. Max( ) is the maximum value of the resistance and Min( ) is the
minimum value of the resistance over the temperature range.
20. Compliance to datasheet limits is assured by one or more methods: production test, characterization and/or design.
21. It is preferable to ramp up both the VLOGIC and the VCC supplies at the same time. If this is not possible, it is recommended to ramp-up the VLOGIC
first followed by the VCC.
22. VMATCH = [V(RWx)i - V(RWy)i]/LSB, for i = 1 to 255, x = 0 to 1 and y = 0 to 1.
23. RMATCH = (RWi,x - RWi,y)/MI, for i = 1 to 255 , x = 0 to 1 and y = 0 to 1.
8
FN7870.0
June 21, 2011