English
Language : 

ISL6740 Datasheet, PDF (7/29 Pages) Intersil Corporation – Flexible Double Ended Voltage and Current Mode PWM Controllers
ISL6740, 1SL6741
Absolute Maximum Ratings
Supply Voltage, VDD . . . . . . . . . . . . . . . . . . . GND - 0.3V to +20.0V
OUTA, OUTB, Signal Pins . . . . . . . . . . . . . . . . .GND - 0.3V to VREF
VREF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . GND - 0.3V to 6.0V
Peak GATE Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.5A
ESD Classification
Human Body Model (Per MIL-STD-883 Method 3015.7) . . .1500V
Charged Device Model (Per EOS/ESD DS5.3, 4/14/93) . . .1000V
Thermal Information
Thermal Resistance Junction to Ambient (Typical)
θJA (°C/W)
16 Lead SOIC (Note 1) . . . . . . . . . . . . . . . . . . . . . .
77
16 Lead TSSOP (Note 1) . . . . . . . . . . . . . . . . . . . . .
102
Maximum Junction Temperature . . . . . . . . . . . . . . .-55°C to +150°C
Maximum Storage Temperature Range . . . . . . . . . .-65°C to +150°C
Pb-free reflow profile . . . . . . . . . . . . . . . . . . . . . . . . . .see link below
http://www.intersil.com/pbfree/Pb-FreeReflow.asp
Operating Conditions
Temperature Range
ISL6740Ix . . . . . . . . . . . . . . . . . . . . . . . . . . . . .-40°C to +105°C
ISL6741Ix . . . . . . . . . . . . . . . . . . . . . . . . . . . . .-40°C to +105°C
Supply Voltage Range (Typical). . . . . . . . . . . . . . . . 9VDC - 16VDC
CAUTION: Do not operate at or near the maximum ratings listed for extended periods of time. Exposure to such conditions may adversely impact product reliability and
result in failures not covered by warranty.
1. θJA is measured with the component mounted on a high effective thermal conductivity test board in free air. See Tech Brief TB379 for details.
2. All voltages are with respect to GND.
Electrical Specifications
Recommended operating conditions unless otherwise noted. Refer to Block Diagram and Typical Application
Schematic. 9V < VDD < 20 V, RTD = 51.1kΩ, RTC = 10kΩ, CT = 470pF, TA = -40°C to +105°C (Note 3), Typical
values are at TA = +25°C
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNITS
SUPPLY VOLTAGE
Start-Up Current, IDD
Operating Current, IDD
UVLO START Threshold
VDD < START Threshold
RLOAD, COUTA,B = 0
COUTA,B = 1nF
-
95
140
μA
-
5.0
8.0
mA
-
7.0
12.0
mA
6.50
7.25
8.00
V
UVLO STOP Threshold
6.00
6.75
7.50
V
Hysteresis
0.25
0.50
0.75
V
REFERENCE VOLTAGE
Overall Accuracy
Long Term Stability
Fault Voltage
IVREF = 0, -20mA
TA = +125°C, 1000 hours (Note 4)
4.900 5.000
5.050
V
-
3
-
mV
4.10
4.55
4.75
V
VREF Good Voltage
Hysteresis
4.25
4.75 VREF - 0.05
V
75
165
250
mV
Operational Current (source)
-20
-
-
mA
Operational Current (sink)
5
-
-
mA
Current Limit
-25
-
-100
mA
CURRENT SENSE
Current Limit Threshold
CS to OUT Delay
VERROR = VREF
0.55
0.6
0.65
V
-
35
50
ns
CS Sink Current
-
10
-
mA
Input Bias Current
-1.00
-
1.00
μA
CS to PWM Comparator Input Offset (ISL6741) (Note 4)
-
80
-
mV
Gain (ISL6741)
SCSET Input Impedance
ACS = ΔVERROR/ΔVCS (Note 4)
-
4
1
-
-
V/V
-
MΩ
SC Setpoint Accuracy
-
10
-
%
7
FN9111.4