English
Language : 

ISL6595 Datasheet, PDF (7/22 Pages) Intersil Corporation – Digital Multiphase Controller
ISL6595
Electrical Specifications
VDD = +3.3V, TC = +25°C, unless otherwise specified. Parameters with MIN and/or MAX limits are 100% tested
at +25°C, unless otherwise specified. Temperature limits established by characterization and are not
production tested (Continued)
PARAMETER
SYMBOL
TEST CONDITIONS
MIN
TYP
MAX UNITS
PWM[6:1] OUTPUTS
Output LOW Voltage
Output LOW Voltage
FAULT1, FAULT2 OUTPUTS
VOL
VOL
Open drain output, ILOAD = +5mA
Open drain output, ILOAD = +16mA
-
-
0.4
V
-
0.5
-
V
Output LOW Voltage
Output LOW Voltage
Output HIGH Voltage
Output Current in Hi-Z State
CAL_CUR_EN OUTPUT
VOL
VOL
VOH
IOZ
ILOAD = +5mA
Open drain output, ILOAD = +16mA
ILOAD = -5mA
VOUT = 1.65V
-
-
0.4
V
-
0.5
-
V
2.4
-
-
V
-10
-
10
µA
Output LOW Voltage
Output HIGH Voltage
VR_READY OUTPUT (Note 3)
VOL
VOH
ILOAD = +500µA
ILOAD = -1mA
-
-
0.4
V
2.8
-
-
V
Output Low Voltage
Output High Voltage
Transition Edge Rate
VOL
VOH
ILOAD = ±500µA
ILOAD = ±500µA
From 10% to 90%
0
-
0.3
V
0.8
-
3.3
V
-
-
150
ns
SETPOINT ACCURACY
Setpoint Accuracy (Note 5)
VREF
VID = 1.20V, TA = +25°C
-8
VID = 0.85V to 1.65V, TA = 0°C to +85°C
-10
Voltage Conversion Gain Error (Note 5)
GREF3 TA = +25°C
-
TA = 0°C to +85°C
-
Voltage Conversion ADC Error INL (Note 5) INLVADC TA = +25°C
-
TA = 0°C to +85°C
-
SWITCHING FREQUENCY, RANGE 100kHz TO 2MHz (Note 6)
-
+8
mV
-
+10
mV
-
0.4
%
-
0.75
%
-
8.5
mV
-
9
mV
Frequency Accuracy (Note 6)
FAULT MONITORS
TA = +25°C
-5
-
5
%
TA = 0°C to +85°C, VDD = 3.0V to 3.6V
-10
-
10
%
OUVP Threshold Voltage
OOVP Threshold Accuracy (Note 5)
VOUVP
Programmable from 0.225V to 1.8V
0.35 0.40 0.45
V
-50
-
50
mV
Internal OTP Threshold Range
See PTAT shut_down in Table 4
-
-
-
Internal OTP Threshold Accuracy
-10
-
10
°C
IUVP Rising Threshold Voltage
VIUVP_LH
1.15
-
1.25
V
IUVP Falling Threshold Voltage
VIUVP_HL
0.95
-
1.05
V
NOTES:
3. An open input will float to the logic-1 state. This feature is not intended as a replacement for an external pull-up resistor when the input is driven
by an open-drain driver.
4. VIH(max) is guaranteed but not tested. Input current is typically less than 2mA at VIH = +4V. In applications requiring +5.5V tolerance, the device
must be driven by a source impedance greater than 1kΩ.
5. Limits established by characterization and are not production tested.
6. Setting is programmable.
7
FN9192.2
December 4, 2008