English
Language : 

ISL6595 Datasheet, PDF (21/22 Pages) Intersil Corporation – Digital Multiphase Controller
ISL6595
REGISTER
oovp_limit [5:0]
fault1_mask[12:0]
fault2_mask[12:0]
shutdown_mask[10:0]
ch_mask[6:1]
TABLE 4. KEY REGISTERS (Continued)
DESCRIPTION
FORMAT
Output overvoltage protect threshold. Tracking VID over R/W
voltage threshold.
FAULT1, FAULT2 pin output masks. Inputs are enabled for
reporting when set to logic 1. If multiple inputs are selected,
output is “OR” of selected input signals.
15 = Current ADC over range
14 = Load current monitor
13 = Average total current fault
12 = NVM fault
11 = Internal bus fault
10 = IUVP
9 = OUVP
8 = OOVP
7 = VR_HOT alert
6 = VR_FAN alert
5 = External (thermistor) temp alert
4 = External (thermistor) temp shutdown
3 = Internal (PTAT) temp alert
2 = Internal (PTAT) temp shutdown
1 = MHz controller fault
0 = Calibration fault
Shutdown control mask. Inputs are enabled for shutdown R/W
when set to logic 1. If multiple inputs are selected, output is
“OR” of selected input signals.
11= Averal total current fault
10 = Total current fault during active regulation
9 = Total current fault during soft-start
8 = Individual phase current fault during active regulation
7 = Individual phase current fault during soft-start
6 = Current ADC over range fault
5 = IUVP
4 = OUVP
3 = OOVP
2 = Thermistor temp shutdown
1 = PTAT temp shutdown 0 = Calibration fault
0 = Calibration fault
Channel mask. Selects number of active phases. Phases R/W
must be selected in sequential order.
000011 = 2-phase operation
000111 = 3-phase operation
001111 = 4-phase operation
011111 = 5-phase operation
111111 = 6-phase operation
RANGE
MIN
MAX
0.0mV
787.5mV
RESOLUTION
12.5mV
All Intersil U.S. products are manufactured, assembled and tested utilizing ISO9000 quality systems.
Intersil Corporation’s quality certifications can be viewed at www.intersil.com/design/quality
Intersil products are sold by description only. Intersil Corporation reserves the right to make changes in circuit design, software and/or specifications at any time without
notice. Accordingly, the reader is cautioned to verify that data sheets are current before placing orders. Information furnished by Intersil is believed to be accurate and
reliable. However, no responsibility is assumed by Intersil or its subsidiaries for its use; nor for any infringements of patents or other rights of third parties which may result
from its use. No license is granted by implication or otherwise under any patent or patent rights of Intersil or its subsidiaries.
For information regarding Intersil Corporation and its products, see www.intersil.com
21
FN9192.2
December 4, 2008