82C54
Functional Description
General
The 82C54 is a programmable interval timer/counter
designed for use with microcomputer systems. It is a general
purpose, multi-timing element that can be treated as an
array of I/O ports in the system software.
The 82C54 solves one of the most common problems in any
microcomputer system, the generation of accurate time
delays under software control. Instead of setting up timing
loops in software, the programmer configures the 82C54 to
match his requirements and programs one of the counters
for the desired delay. After the desired delay, the 82C54 will
interrupt the CPU. Software overhead is minimal and
variable length delays can easily be accommodated.
Some of the other computer/timer functions common to
microcomputers which can be implemented with the 82C54
are:
• Real time clock
• Event counter
• Digital one-shot
• Programmable rate generator
• Square wave generator
• Binary rate multiplier
• Complex waveform generator
• Complex motor controller
Data Bus Buffer
This three-state, bi-directional, 8-bit buffer is used to
interface the 82C54 to the system bus (see Figure 1).
D7 - D0 8
DATA/
BUS
BUFFER
COUNTER
0
CLK 0
GATE 0
OUT 0
Read/Write Logic
The Read/Write Logic accepts inputs from the system bus and
generates control signals for the other functional blocks of the
82C54. A1 and A0 select one of the three counters or the
Control Word Register to be read from/written into. A “low” on
the RD input tells the 82C54 that the CPU is reading one of the
counters. A “low” on the WR input tells the 82C54 that the CPU
is writing either a Control Word or an initial count. Both RD and
WR are qualified by CS; RD and WR are ignored unless the
82C54 has been selected by holding CS low.
Control Word Register
The Control Word Register (Figure 2) is selected by the
Read/Write Logic when A1, A0 = 11. If the CPU then does a
write operation to the 82C54, the data is stored in the
Control Word Register and is interpreted as a Control Word
used to define the Counter operation.
The Control Word Register can only be written to; status
information is available with the Read-Back Command.
D7 - D0 8
DATA/
BUS
BUFFER
COUNTER
0
CLK 0
GATE 0
OUT 0
RD
WR
READ/
WRITE
A0
LOGIC
A1
CS
CONTROL
WORD
REGISTER
COUNTER
1
CLK 1
GATE 1
OUT 1
COUNTER
2
CLK 2
GATE 2
OUT 2
RD
WR
READ/
WRITE
A0
LOGIC
A1
CS
CONTROL
WORD
REGISTER
COUNTER
1
CLK 1
GATE 1
OUT 1
COUNTER
2
CLK 2
GATE 2
OUT 2
FIGURE 1. DATA BUS BUFFER AND READ/WRITE LOGIC
FUNCTIONS
6
FIGURE 2. CONTROL WORD REGISTER AND COUNTER
FUNCTIONS
Counter 0, Counter 1, Counter 2
These three functional blocks are identical in operation, so
only a single Counter will be described. The internal block
diagram of a signal counter is shown in Figure 3. The
counters are fully independent. Each Counter may operate in
a different Mode.
The Control Word Register is shown in the figure; it is not
part of the Counter itself, but its contents determine how the
Counter operates.