English
Language : 

HCS139MS Datasheet, PDF (5/9 Pages) Intersil Corporation – Radiation Hardened Dual 2-to-4 Line Decoder/Demultiplexer
Specifications HCS139MS
TABLE 4. DC POST RADIATION ELECTRICAL PERFORMANCE CHARACTERISTICS (Continued)
PARAMETER
Input Leakage Current
Noise Immunity
Functional Test
Propagation Delay
A0, A1 to Output
Propagation Delay
Enable to Output
SYMBOL
(NOTES 1, 2)
CONDITIONS
IIN
VCC = 5.5V, VIN = VCC or GND
FN
VCC = 4.5V, VIH = 3.15V,
VIL = 1.35V, (Note 3)
TPHL,
TPLH
VCC = 4.5V
TPHL,
TPLH
VCC = 4.5V
TEMPERATURE
+25oC
+25oC
200K RAD
LIMITS
MIN MAX
-
±5
-
-
+25oC
2
27
+25oC
2
27
NOTES:
1. All voltages referenced to device GND.
2. AC measurements assume RL = 500Ω, CL = 50pF, Input TR = TF = 3ns, VIL = GND, VIH = VCC
3. For functional tests VO ≥ 4.0V is recognized as a logic “1”, and VO ≤ 0.5V is recognized as a logic “0”.
UNITS
µA
-
ns
ns
TABLE 5. BURN-IN AND OPERATING LIFE TEST, DELTA PARAMETERS (+25oC)
PARAMETER
GROUP B
SUBGROUP
DELTA LIMIT
ICC
5
12µA
IOL/IOH
5
-15% of 0 Hour
TABLE 6. APPLICABLE SUBGROUPS
CONFORMANCE GROUPS
METHOD
GROUP A SUBGROUPS
READ AND RECORD
Initial Test (Preburn-In)
100%/5004
1, 7, 9
ICC, IOL/H, IOZL/H
Interim Test I (Postburn-In)
100%/5004
1, 7, 9
ICC, IOL/H, IOZL/H
Interim Test II (Postburn-In)
100%/5004
1, 7, 9
ICC, IOL/H, IOZL/H
PDA
100%/5004
1, 7, 9, Deltas
Interim Test III (Postburn-In)
100%/5004
1, 7, 9
ICC, IOL/H, IOZL/H
PDA
100%/5004
1, 7, 9, Deltas
Final Test
100%/5004
2, 3, 8A, 8B, 10, 11
Group A (Note 1)
Sample/5005
1, 2, 3, 7, 8A, 8B, 9, 10, 11
Group B
Subgroup B-5
Sample/5005 1, 2, 3, 7, 8A, 8B, 9, 10, 11, Deltas Subgroups 1, 2, 3, 9, 10, 11
Subgroup B-6
Sample/5005
1, 7, 9
Group D
Sample/5005
1, 7, 9
NOTE:
1. Alternate Group A testing in accordance with Method 5005 of Mil-Std-883 may be exercised.
Spec Number 518832