English
Language : 

ISL6161 Datasheet, PDF (4/11 Pages) Intersil Corporation – Dual Power Distribution Controller
ISL6161
Absolute Maximum Ratings TA = +25°C
VDD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -0.3V to +16V
12VG, CPUMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -0.3V to 21V
12VISEN, 12VS . . . . . . . . . . . . . . . . . . . . . . . . . . -5V to VDD + 0.3V
3VISEN, 3VS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -5V to 7.5V
PGOOD, RILIM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -0.3V to 7.5V
ENABLE, CTIM, 3VG . . . . . . . . . . . . . . . . . . . . . -0.3V to VDD + 0.3V
ESD Classification . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2kV (Class 2)
Thermal Information
Thermal Resistance (Typical, Note 1)
θJA (°C/W)
SOIC Package . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
67
Maximum Junction Temperature (Plastic Package) . . . . . . . +150°C
Maximum Storage Temperature Range . . . . . . . . . .-65°C to +150°C
Pb-Free Reflow Profile. . . . . . . . . . . . . . . . . . . . . . . . .see link below
http://www.intersil.com/pbfree/Pb-FreeReflow.asp
Operating Conditions
VDD Supply Voltage Range . . . . . . . . . . . . . . . . . . +10.5V to +13.2V
Temperature Range (TA)
ISL6161IB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .-40°C to +85°C
ISL6161CB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to +70°C
CAUTION: Do not operate at or near the maximum ratings listed for extended periods of time. Exposure to such conditions may adversely impact product reliability and
result in failures not covered by warranty.
NOTES:
1. θJA is measured with the component mounted on a high effective thermal conductivity test board in free air. See Tech Brief TB379 for details.
2. All voltages are relative to GND, unless otherwise specified.
Electrical Specifications
VDD = 12V, CVG = 0.01µF, CTIM = 0.1µF, RSENSE = 0.1Ω, CBULK = 220µF, ESR = 0.5Ω, TA = TJ = -40°C to
+85°C, Unless Otherwise Specified. Parameters with MIN and/or MAX limits are 100% tested at +25°C,
unless otherwise specified. Temperature limits established by characterization and are not
production tested.
PARAMETER
SYMBOL
TEST CONDITIONS
MIN
TYP
MAX UNITS
12V CONTROL SECTION
Current Limit Threshold Voltage
(Voltage Across Sense Resistor)
3x Current Limit Threshold Voltage
(Voltage Across Sense Resistor)
±20% Current Limit Response Time
(Current within 20% of Regulated Value)
±10% Current Limit Response Time
(Current within 10% of Regulated Value)
±1% Current Limit Response Time
(Current within 1% of Regulated Value)
Response Time to Dead Short
Gate Turn-On Time
Gate Turn-On Current
3x Gate Discharge Current
VIL12V
3 x VIL12V
20%iLrt
10%iLrt
1%iLrt
RTSHORT
tON12V
ION12V
3XdisI
RILIM = 10kΩ
RILIM = 5kΩ
RILIM = 10kΩ
RILIM = 5kΩ
200% Current Overload, RILIM = 10kΩ,
RSHORT = 6.0Ω
200% Current Overload, RILIM = 10kΩ,
RSHORT = 6.0Ω
200% Current Overload, RILIM = 10kΩ,
RSHORT = 6.0Ω
C12VG = 0.01µF
C12VG = 0.01µF
C12VG = 0.01µF
12VG = 18V
92
100
108
mV
47
53
59
mV
250
300
350
mV
100
165
210
mV
-
2
-
µs
-
4
-
µs
-
10
-
µs
-
500
-
ns
-
12
-
ms
8
10
12
µA
-
0.75
-
A
12V Undervoltage Threshold
Charge Pumped 12VG Voltage
3.3V CONTROL SECTION
12VVUV
V12VG
CPUMP = 0.1µF
10.5
10.8
11.0
V
16.8
17.3
17.9
V
Current Limit Threshold Voltage
(Voltage Across Sense Resistor)
3x Current Limit Threshold Voltage
(Voltage Across Sense Resistor)
±20% Current Limit Response Time
(Current within 20% of Regulated Value)
±10% Current Limit Response Time
(Current within 10% of Regulated Value)
VIL3V
3 x VIL3V
RILIM = 10kΩ
RILIM = 5kΩ
RILIM = 10kΩ
RILIM = 5kΩ
200% Current Overload, RILIM = 10kΩ,
RSHORT = 2.5Ω
200% Current Overload, RILIM = 10kΩ,
RSHORT = 2.5Ω
92
100
108
mV
47
53
59
mV
250
300
350
mV
100
155
210
mV
-
2
-
µs
-
4
-
µs
4
FN9104.4
October 2, 2008