ISL6334 Datasheet, PDF (19/30 Pages) Intersil Corporation – VR11.1, 4-Phase PWM Controller with Light Load Efficiency Enhancement and Load Current Monitoring
ISL6334, ISL6334A
The regulated output voltage is reduced by the droop voltage
VDROOP. The output voltage as a function of load current is
derived by combining Equation 8 with the appropriate
sample current expression defined by the current sense
method employed, as shown in Equation 9:
VOUT
=
VREF
–
VO
F
S
–
⎛
⎜
⎝
I--L----O----A----D--
N
------R----X-------
RISEN
⎞
R F B⎠⎟
(EQ. 9)
where VREF is the reference voltage, VOFS is the
programmed offset voltage, ILOAD is the total output current
of the converter, RISEN is the sense resistor connected to
the ISEN+ pin, and RFB is the feedback resistor, N is the
active channel number, and RX is the DCR, or RSENSE
depending on the sensing method.
Therefore, the equivalent loadline impedance, i.e. Droop
impedance, is equal to Equation 10:
RLL
=
--R----F----B--
N
-----R-----X-------
RISEN
(EQ. 10)
Output-Voltage Offset Programming
The ISL6334, ISL6334A allows the designer to accurately
adjust the offset voltage. When a resistor, ROFS, is
connected between OFS to VCC, the voltage across it is
regulated to 1.6V. This causes a proportional current (IOFS)
to flow into OFS. If ROFS is connected to ground, the voltage
across it is regulated to 0.4V, and IOFS flows out of OFS. A
resistor between DAC and REF, RREF, is selected so that
the product (IOFS x ROFS) is equal to the desired offset
voltage. These functions are shown in Figure 7.
FB
DYNAMIC
VID D/A
DAC
RREF
E/A
REF
CREF
VCC
OR
GND
-
1.6V
+
+
0.4V
-
ROFS
OFS
ISL6334, ISL6334A
VCC
GND
FIGURE 7. OUTPUT VOLTAGE OFFSET PROGRAMMING
Once the desired output offset voltage has been determined,
use Equations 11 and 12 to calculate ROFS:
For Positive Offset (connect ROFS to VCC):
ROFS
=
1----.--6----×-----R-----R----E----F-
VOFFSET
(EQ. 11)
For Negative Offset (connect ROFS to GND):
ROFS
=
0----.--4----×-----R-----R----E----F-
VOFFSET
(EQ. 12)
Dynamic VID
Modern microprocessors need to make changes to their
core voltage as part of normal operation. They direct the
core-voltage regulator to do this by making changes to the
VID inputs during regulator operation. The power
management solution is required to monitor the DAC inputs
and respond to on-the-fly VID changes in a controlled
manner. Supervising the safe output voltage transition within
the DAC range of the processor without discontinuity or
disruption is a necessary function of the core-voltage
regulator.
In order to ensure the smooth transition of output voltage
during VID change, a VID step change smoothing network,
composed of RREF and CREF, as shown in Figure 7, can be
used. The selection of RREF is based on the desired offset
voltage as detailed in “Output-Voltage Offset Programming”
on page 19. The selection of CREF is based on the time
duration for 1-bit VID change and the allowable delay time.
Assuming the microprocessor controls the VID change at
1-bit every tVID, the relationship between the time constant
of RREF and CREF network and tVID is given by Equation 13.
CREF RREF = tVID
(EQ. 13)
During dynamic VID transition and VID steps up, the
overcurrent trip point increases by 140% to avoid falsely
triggering OCP circuits, while the overvoltage trip point is set
to its maximum VID OVP trip level. If the dynamic VID occurs
at PSI# asserted, the system should exit PSI# and complete
the transition, and then resume PSI# operation 50µs after
the transition.
Operation Initialization
Prior to converter initialization, proper conditions must exist
on the enable inputs and VCC. When the conditions are met,
the controller begins soft-start. Once the output voltage is
within the proper window of operation, VR_RDY asserts
logic high.
Enable and Disable
While in shutdown mode, the PWM outputs are held in a
high-impedance state to assure the drivers remain off. The
following input conditions must be met before the ISL6334,
ISL6334A is released from shutdown mode.
19
FN6482.0
February 26, 2008