English
Language : 

ISL12028 Datasheet, PDF (16/28 Pages) Intersil Corporation – Real Time Clock/Calendar with EEPROM
ISL12028
lower. In this mode, accidental operation from the battery is
prevented since the battery backup input will only be used
when the VDD supply is shut off.
To select Option 1, BSW bit in the Power Register must be
set to “BSW = 0”. A description of power switchover follows
Standard Mode Power Switchover
• Normal Operating Mode (VDD) to Battery Backup Mode
(VBAT)
To transition from the VDD to VBAT mode, both of the
following conditions must be met:
- Condition 1:
VDD < VBAT - VBATHYS
where VBATHYS ≈ 50mV
- Condition 2:
VDD < VTRIP
where VTRIP ≈ 2.2V
• Battery Backup Mode (VBAT) to Normal Mode (VDD)
The ISL12028 device will switch from the VBAT to VDD mode
when one of the following conditions occurs:
- Condition 1:
VDD > VBAT + VBATHYS
where VBATHYS ≈ 50mV
- Condition 2:
VDD > VTRIP + VTRIPHYS
where VTRIPHYS ≈ 30mV
There are two discrete situations that are possible when
using Standard Mode: VBAT< VTRIP and VBAT >VTRIP.
These two power control situations are illustrated in Figures
13 and 14.
BATTERY BACKUP
VDD
MODE
VTRIP
VBAT
2.2V
1.8V
VBAT - VBATHYS
VBAT + VBATHYS
FIGURE 13. BATTERY SWITCHOVER WHEN VBAT < VTRIP
VDD
VBAT
VTRIP
VTRIP
BATTERY BACKUP
MODE
3.0V
2.2V
VTRIP + VTRIPHYS
FIGURE 14. BATTERY SWITCHOVER WHEN VBAT > VTRIP
OPTION 2 - LEGACY POWER CONTROL MODE
(DEFAULT)
The Legacy Mode follows conditions set in X1226 products.
In this mode, switching from VDD to VBAT is simply done by
comparing the voltages and the device operates from
whichever is the higher voltage. Care should be taken when
changing from Normal to Legacy Mode. If the VBAT voltage is
higher than VDD, then the device will enter battery back up
and unless the battery is disconnected or the voltage
decreases, the device will no longer operate from VDD.
To select the Option 2, BSW bit in the Power Register must
be set to “BSW = 1”
• Normal Mode (VDD) to Battery Backup Mode (VBAT)
To transition from the VDD to VBAT mode, the following
conditions must be met:
VDD < VBAT - VBATHYS
• Battery Backup Mode (VBAT) to Normal Mode (VDD)
The device will switch from the VBAT to VDD mode when the
following condition occurs:
VDD > VBAT +VBATHYS
The Legacy Mode power control conditions are illustrated in
Figure 15.
VBAT
VDD
Off
VOLTAGE
On
In
FIGURE 15. BATTERY SWITCHOVER IN LEGACY MODE
16
FN8233.5
October 18, 2006