English
Language : 

ISL70419SEH Datasheet, PDF (15/22 Pages) Intersil Corporation – Spectral analysis equipment
ISL70419SEH
Post High Dose Radiation Characteristics Unless otherwise specified, VS ± 15V, VCM = 0, VO = 0V, TA = +25°C. This data is
typical mean test data post radiation exposure at a high dose rate of 50 - 300rad(Si)/s. This data is intended to show typical parameter shifts due to high
dose rate radiation. These are not limits nor are they guaranteed.
3
25
20
2
15
1
10
5
0
0
-1
ICC HDR BIASED
IEE HDR BIASED
-2
ICC HDR GROUNDED
IEE HDR GROUNDED
-5
-10
CHA HDR BIASED
CHB HDR BIASED
-15
CHC HDR BIASED
CHD HDR BIASED
-20
CHA HDR GROUNDED
CHB HDR GROUNDED
CHC HDR GROUNDED
CHD HDR GROUNDED
-3
0
50
100
150
200
250
300
krad(Si)
-25
0
50
100
150
200
250
300
krad(Si)
FIGURE 43. SUPPLY CURRENT vs HIGH DOSE RATE RADIATION
FIGURE 44. VOS vs HIGH DOSE RATE RADIATION
5
4
3
2
1
0
-1
-2
CHA HDR BIASED
-3
CHB HDR BIASED
CHC HDR BIASED
-4
CHD HDR BIASED
CHA HDR GROUNDED
CHB HDR GROUNDED
CHC HDR GROUNDED
CHD HDR GROUNDED
-5
0
50
100
150
200
250
300
krad(Si)
FIGURE 45. IB+ vs HIGH DOSE RATE RADIATION
5
4
3
2
1
0
-1
-2
CHA HDR BIASED
-3
CHB HDR BIASED
CHC HDR BIASED
-4
CHD HDR BIASED
CHA HDR GROUNDED
CHB HDR GROUNDED
CHC HDR GROUNDED
CHD HDR GROUNDED
-5
0
50
100
150
200
250
300
krad(Si)
FIGURE 46. IB- vs HIGH DOSE RATE RADIATION
5
4
3
2
1
0
-1
CHA HDR BIASED
-2
CHB HDR BIASED
-3
CHC HDR BIASED
CHD HDR BIASED
-4
CHA HDR GROUNDED
CHB HDR GROUNDED
CHC HDR GROUNDED
CHD HDR GROUNDED
-5
0
50
100
150
200
250
300
krad(Si)
FIGURE 47. IOSvs HIGH DOSE RATE RADIATION
Submit Document Feedback 15
July 11, 2014
FN8653.0