X9259
DC Electrical Specifications Over the recommended operating conditions unless otherwise specified.
SYMBOL
PARAMETER
ICC1
VCC supply current
(active)
ICC2
VCC supply current
(non-volatile write)
TEST CONDITIONS
fSCL = 400kHz; VCC = +6V;
SDA = Open; (for 2-Wire, Active, Read and
Volatile Write States only)
fSCL = 400kHz; VCC = +6V;
SDA = Open; (for 2-Wire, Active,
Non-volatile Write State only)
LIMITS
MIN
TYP
MAX
UNITS
3
mA
5
mA
ISB
VCC current (standby)
ILI
ILO
VIH
VIL
VOL
VOH
VOH
Input leakage current
Output leakage current
Input HIGH voltage
Input LOW voltage
Output LOW voltage
Output HIGH voltage
Output HIGH voltage
VCC = +6V; VIN = VSS or VCC; SDA = VCC;
(for 2-Wire, Standby State only)
VIN = VSS to VCC
VOUT = VSS to VCC
IOL = 3mA
IOH = -1mA, VCC ≥ +3V
IOH = -0.4mA, VCC ≤ +3V
VCC x 0.7
-1
VCC - 0.8
VCC - 0.4
5
µA
10
µA
10
µA
VCC + 1
V
VCC x 0.3
V
0.4
V
V
V
Endurance and Data Retention
PARAMETER
Minimum endurance
Data retention
MIN
100,000
100
UNITS
Data changes per bit per register
years
Capacitance
SYMBOL
CIN/OUT(6)
CIN(6)
TEST
Input / Output capacitance (SDA)
Input capacitance (SCL, WP, A2, A1 and A0)
Power-up Timing
SYMBOL
tr VCC(6)
tPUR(7)
tPUW(7)
PARAMETER
VCC Power-up rate
Power-up to initiation of read operation
Power-up to initiation of write operation
MAX
8
6
MIN
0.2
UNITS
pF
pF
TEST CONDITIONS
VOUT = 0V
VIN = 0V
MAX
50
1
50
UNITS
V/ms
ms
ms
A.C. Test Conditions
Input Pulse Levels
Input rise and fall times
Input and output timing level
VCC x 0.1 to VCC x 0.9
10ns
VCC x 0.5
Notes: (6) This parameter is not 100% tested
(7) tPUR and tPUW are the delays required from the time the (last) power supply (VCC-) is stable until the specific instruction can be issued.
These parameters are periodically sampled and not 100% tested.