ABSOLUTE MAXIMUM RATINGS
Temperature under bias ................... -65°C to +135°C
Storage temperature ........................ -65°C to +150°C
Voltage on any pin with respect to VSS... -1.0V to +7V
D.C. output current ............................................... 5mA
Lead temperature (soldering, 10 seconds) ........ 300°C
RECOMMENDED OPERATING CONDITIONS
Temperature
Commercial
Industrial
Min.
0°C
-40°C
Max.
70°C
+85°C
COMMENT
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
This is a stress rating only; functional operation of the
device (at these or any other conditions above those
listed in the operational sections of this specification) is
not implied. Exposure to absolute maximum rating con-
ditions for extended periods may affect device reliability.
Option
-2.7 and -2.7A
Blank and -4.5A
Supply Voltage Limits
2.7V to 5.5V
4.5V to 5.5V
D.C. OPERATING CHARACTERISTICS (Over the recommended operating conditions unless otherwise specified.)
Symbol
ICC1(1)
ICC2(1)
ISB(2)
Parameter
Active Supply Current Read
Active Supply Current Write
Standby Current DC (WDT off)
VCC = 2.7 to 5.5V
Min
Max
1.0
3.0
1
ISB(2) Standby Current DC (WDT on)
20
ILI
Input Leakage Current
10
ILO
Output Leakage Current
10
VIL(3)
VIH(3)
VHYS
VOL
Input LOW Voltage
Input nonvolatile
Schmitt Trigger Input Hysteresis
Fixed input level
VCC related level
Output LOW Voltage
-0.5
VCC x 0.7
0.2
.05 x VCC
VCC x 0.3
VCC + 0.5
0.4
Unit
mA
mA
µA
µA
µA
µA
V
V
Test Conditions
VIL = VCC x 0.1, VIH = VCC x 0.9
fSCL = 400kHz, SDA = Commands
VSDA = VSCL = VSB
Others = GND or VSB
VSDA=VSCL=VSB
Others = GND or VSB
VIN = GND to VCC
VSDA = GND to VCC
Device is in Standby(2)
V
V
V IOL = 3.0mA (2.7- 5.5V)
Notes: (1) The device enters the Active state after any start, and remains active until: 9 clock cycles later if the Device Select Bits in the Slave
Address Byte are incorrect; 200ns after a stop ending a read operation; or tWC after a stop ending a write operation.
(2) The device goes into Standby: 200ns after any stop, except those that initiate a nonvolatile write cycle; tWC after a stop that initiates a
nonvolatile cycle; or 9 clock cycles after any start that is not followed by the correct Device Select Bits in the Slave Address Byte.
(3) VIL Min. and VIH Max. are for reference only and are not tested.
14
FN8120.0