English
Language : 

X4003 Datasheet, PDF (14/17 Pages) Xicor Inc. – CPU Supervisor
X4003, X4005
RESET/RESET Output Timing
Symbol
Parameter
tWDO
tCST
tRST
Watchdog time out period,
WD1 = 1, WD0 = 1 (factory setting)
WD1 = 1, WD0 = 0
WD1 = 0, WD0 = 1
WD1 = 0, WD0 = 0
CS pulse width to reset the watchdog
Reset time out
VTRIP Programming Timing Diagram
tTHD
tTSU
VTRIP
Min.
100
450
1
400
100
Typ.
OFF
200
600
1.4
200
Max.
300
800
2
400
Unit
ms
ms
sec
ns
ms
VCC
(VTRIP)
VP
WP
tVPO
tRP
tVPH
00h
01h or 03h
tVPS
A0h
SCL
SDA
VTRIP Programming Parameters
Parameter
Description
tVPS
tVPH
tTSU
tTHD
tWC
tVPO
tRP
VP
VTRAN
Vta1
Vta2
VTRIP program enable voltage setup time
VTRIP program enable voltage hold time
VTRIP setup time
VTRIP hold (stable) time
VTRIP write cycle time
VTRIP program enable voltage off time (between successive adjustments)
VTRIP program recovery period (between successive adjustments)
Programming voltage
VTRIP programmed voltage range
Initial VTRIP program voltage accuracy (VCC applied - VTRIP) (Programmed at 25°C.)
Subsequent VTRIP program voltage accuracy [(VCC applied - Vta1) - VTRIP.
Programmed at 25°C.)
Vtr
VTRIP program voltage repeatability (Successive program operations. Programmed
at 25°C.)
Vtv
VTRIP program variation after programming (0-75°C). (programmed at 25°C)
VTRIP programming parameters are periodically sampled and are not 100% tested.
Min. Max. Unit
1
µs
1
µs
1
µs
10
ms
10 ms
0
µs
10
ms
15 18 V
1.7 5.0 V
-0.1 +0.4 V
-25 +25 mV
-25 +25 mV
-25 +25 mV
14
FN8113.0
March 15, 2005