DC Electrical Specifications Over the recommended operating conditions unless otherwise specified.
LIMITS
SYMBOL
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
ICC1
VCC supply current
fSCL = 400kHz; VCC = +6V;
3
(active)
SDA = Open; (for 2-Wire, Active, Read and
Volatile Write States only)
ICC2
VCC supply current
fSCL = 400kHz; VCC = +6V;
5
(nonvolatile write)
SDA = Open; (for 2-Wire, Active,
Nonvolatile Write State only)
ISB
VCC current (standby)
VCC = +6V; VIN = VSS or VCC; SDA = VCC;
5
(for 2-Wire, Standby State only)
ILI
Input leakage current
ILO
Output leakage current
VIH
Input HIGH voltage
VIL
Input LOW voltage
VOL
Output LOW voltage
VOH
Output HIGH voltage
VOH
Output HIGH voltage
VIN = VSS to VCC
VOUT = VSS to VCC
IOL = 3mA
IOH = -1mA, VCC  +3V
IOH = -0.4mA, VCC  +3V
VCC x 0.7
VCC - 0.8
VCC - 0.4
10
10
VCC x 0.3
0.4
UNITS
mA
mA
µA
µA
µA
V
V
V
V
V
Endurance and Data Retention
PARAMETER
Minimum endurance
Data retention
MIN
100,000
100
UNITS
Data changes per bit per register
years
Capacitance
SYMBOL
TEST
CIN/OUT (Note 15) Input / Output capacitance (SDA)
CIN (Note 15)
Input capacitance (SCL, WP, A2, A1 and A0)
MAX
8
6
UNITS
pF
pF
TEST CONDITIONS
VOUT = 0V
VIN = 0V
Power-up Timing
SYMBOL
tr VCC (Note 15)
tPUR (Note 16)
tPUW (Note 16)
PARAMETER
VCC Power-up rate
Power-up to initiation of read operation
Power-up to initiation of write operation
MIN
MAX
UNITS
0.2
V/ms
1
ms
50
ms
AC Test Conditions
Input Pulse Levels
Input rise and fall times
VCC x 0.1 to VCC x 0.9
10ns
Input and output timing level
VCC x 0.5
NOTES:
15. This parameter is not 100% tested
16. tPUR and tPUW are the delays required from the time the power supply (VCC) is stable until the specific instruction can be issued. These parameters
are periodically sampled and not 100% tested.
Submit Document Feedback 13
FN8169.6
December 12, 2014