English
Language : 

X9241A_07 Datasheet, PDF (13/16 Pages) Intersil Corporation – Quad Digital Controlled Potentionmeters (XDCP™)
X9241A
AC Electrical Specifications (Over recommended operating conditions unless otherwise stated). (Continued)
LIMITS
SYMBOL
PARAMETER
MIN
MAX
(Note 11) (Note 11)
UNIT
tSU:DAT
tHD:DAT
tAA
tDH
tSU:STO
tBUF
tWR
tSTPWV
tCLWV
Data in setup time
Data in hold time
SCL LOW to SDA data out valid
Data out hold time
Stop condition setup time
Bus free time prior to new transmission
Write cycle time (nonvolatile write operation)
Wiper response time from stop generation
Wiper response from SCL LOW
250
ns
0
ns
3500
ns
30
ns
4000
ns
4700
ns
10
ms
500
µs
1000
µs
REFERENCE
FIGURE
NUMBER(S)
10
10
11
11
10 and 12
10
13
13
6
SCL
SDA
tAA
SDAOUT (ACK)
tDH
SDAOUT
FIGURE 11. OUTPUT BUS TIMING
SDAOUT
START CONDITION
SCL
SDA
(DATA IN)
tSU:STA
tHD:STA
FIGURE 12. START STOP TIMING
STOP CONDITION
tSU:STO
SCL
SDA
CLOCK 8
SDAIN
CLOCK 9
STOP
START
tSTPWV
tWR
ACK
WIPER
OUTPUT
FIGURE 13. WRITE CYCLE AND WIPER RESPONSE TIMING
13
FN8164.6
August 31, 2007