English
Language : 

X9241A_07 Datasheet, PDF (12/16 Pages) Intersil Corporation – Quad Digital Controlled Potentionmeters (XDCP™)
Equivalent AC Test Circuit
SDA OUTPUT
5V
1533Ω
100pF
Circuit #3 SPICE Macro Model
MACRO MODEL
RTOTAL
RH
RL
CH
CL
15pF
CW
15pF
25pF
RW
X9241A
Guidelines for Calculating
Typical Values of Bus Pull-Up Resistors
120
100
RMIN =
VCC MAX =1.8kΩ
IOL MIN
80
RMAX =
TR
CBUS
60
MAXIMUM
RESISTANCE
40
20 MIN.
RESISTANCE
0
0
20
40
60
80
100
120
BUS CAPACITANCE (pF)
DCP Wiper Current De-rating Curve
7
6
5
4
3
2
1
0
0 10 20 30 40 50 60 70 80 90
AMBIENT TEMPERATURE (°C)
tHIGH
tLOW
tF
tR
SCL
tSU:STA
tHD:STA
tHD:DAT
tSU:DAT
tSU:STO
SDA
(DATA IN)
tBUF
FIGURE 10. INPUT BUS TIMING
AC Electrical Specifications (Over recommended operating conditions unless otherwise stated).
LIMITS
SYMBOL
PARAMETER
MIN
MAX
(Note 11) (Note 11)
UNIT
fSCL
tLOW
tHIGH
tR
tF
Ti, (Note 11)
tSU:STA
tHD:STA
SCL clock frequency
Clock LOW period
Clock HIGH period
SCL and SDA rise time
SCL and SDA fall time
Noise suppression time constant (glitch filter)
Start condition setup time (for a repeated start condition)
Start condition hold time
0
100
kHz
4700
ns
4000
ns
1000
ns
300
ns
20
ns
4000
ns
4000
ns
REFERENCE
FIGURE
NUMBER(S)
10
10
10
10
10
10
10 and 12
10 and 12
12
FN8164.6
August 31, 2007