English
Language : 

X9401_15 Datasheet, PDF (12/20 Pages) Intersil Corporation – Quad, 64 Tap, Digitally Controlled Potentiometer
X9401
DC Operating Characteristics (Over the recommended operating conditions unless otherwise specified.)
SYMBOL
PARAMETER
TEST CONDITIONS
MIN TYP MAX
(Note 10)
(Note 10) UNIT
ICC1
ICC2
ISB
ILI
ILO
VIH
VIL
VOL
VCC Supply Current (active)
VCC Supply Current (non-volatile write)
VCC Current (standby)
Input Leakage Current
Output Leakage Current
Input HIGH Voltage
Input LOW Voltage
Output LOW Voltage
fSCK = 2MHz, SO = Open, Other Inputs = VSS
fSCK = 2MHz, SO = Open, Other Inputs = VSS
SCK = SI = VSS, Addr. = VSS, CS = VCC
VIN = VSS to VCC
VOUT = VSS to VCC
IOL = 3mA
VCC x 0.7
–0.5
700
µA
3
mA
3
µA
10
µA
10
µA
VCC +0.5 V
VCC x 0.1 V
0.4
V
Endurance and Data Retention
PARAMETER
Minimum endurance
Data retention
MIN.
100,000
100
UNIT
Data changes per bit per register
years
Capacitance
SYMBOL
COUT
(Note 11)
CIN
(Note 11)
Output capacitance (SO)
TEST
Input capacitance (A0, A1, SI, and SCK)
TYP.
8
6
UNIT
pF
pF
TEST CONDITION
VOUT = 0V
VIN = 0V
Power-up Timing
SYMBOL
Input pulse levels = VCC x 0.1 to VCC x 0.9; Input rise and fall times = 10ns; Input and output timing level = VCC x 0.5.
PARAMETER
MIN.
MAX.
UNIT
tr VCC
(Note 11)
VCC Power-up rate
0.2
50
V/ms
tPUR
(Note 12)
Power-up to initiation of read operation
1
ms
tPUW
(Note 12)
Power-up to initiation of write operation
5
ms
NOTES:
11. This parameter is not 100% tested.
12. tPUR and tPUW are the delays required from the time the (last) power supply (VCC-) is stable until the specific instruction can be issued. These
parameters are periodically sampled and not 100% tested.
Equivalent AC Load Circuit
SDA
OUTPUT
5V
1533
100pF
SPICE MACRO MODEL
RTOTAL
RH
CL
CW
10pF
25pF
RW
RL
CL
10pF
12
FN8190.5
September 14, 2015