English
Language : 

X9401_06 Datasheet, PDF (11/19 Pages) Intersil Corporation – Quad, 64 Tap, Digitally Controlled Potentiometer
X9401
D.C. OPERATING CHARACTERISTICS (Over the recommended operating conditions unless otherwise specified.)
Symbol
Parameter
ICC1 VCC supply current (active)
ICC2
ISB
VCC supply current (nonvola-
tile write)
VCC current (standby)
ILI
Input leakage current
ILO Output leakage current
VIH Input HIGH voltage
VIL Input LOW voltage
VOL Output LOW voltage
Min.
Limits
Typ. Max.
400
1
1
VCC x 0.7
-0.5
10
10
VCC + 0.5
VCC x 0.1
0.4
Unit
µA
mA
µA
µA
µA
V
V
V
Test Conditions
fSCK = 2MHz, SO = Open,
Other Inputs = VSS
fSCK = 2MHz, SO = Open,
Other Inputs = VSS
SCK = SI = VSS, Addr. = VSS,
CS = VCC
VIN = VSS to VCC
VOUT = VSS to VCC
IOL = 3mA
ENDURANCE AND DATA RETENTION
Parameter
Minimum endurance
Data retention
Min.
100,000
100
Unit
Data changes per bit per register
years
CAPACITANCE
Symbol
COUT(4)
CIN(4)
Test
Output capacitance (SO)
Input capacitance (A0, A1, SI, and SCK)
POWER-UP TIMING
Symbol
tr VCC(6)
tPUR(5)
tPUW(5)
Parameter
VCC Power-up rate
Power-up to initiation of read operation
Power-up to initiation of write operation
A.C. TEST CONDITIONS
Input pulse levels
Input rise and fall times
Input and output timing level
VCC x 0.1 to VCC x 0.9
10ns
VCC x 0.5
Notes: (4) This parameter is periodically sampled and not 100%
tested
(5) tPUR and tPUW are the delays required from the time
the (last) power supply (VCC-) is stable until the specific
instruction can be issued. These parameters are period-
ically sampled and not 100% tested.
(6) This is not a tested or guaranteed parameter and should
be used only as a guideline.
Max.
8
6
Unit
pF
pF
Test Condition
VOUT = 0V
VIN = 0V
Min.
0.2
Max.
50
1
5
EQUIVALENT A.C. LOAD CIRCUIT
Unit
V/ms
ms
ms
SDA
Output
5V
1533Ω
100pF
SPICE Macro Model
RTOTAL
RH
CL
CW
10pF
25pF
RW
RL
CL
10pF
11
FN8190.3