English
Language : 

X4003-05 Datasheet, PDF (11/16 Pages) Intersil Corporation – Selectable watchdog timer
X4003, X4005
Equivalent AC Load Circuit
5V
5V
SDA
1533
For VOL = 0.4V
and IOL = 3mA
100pF
RESET
RESET
4.6k
100pF
AC Test Conditions
Input pulse levels
Input rise and fall times
Input and output timing levels
Output load
0.1VCC to 0.9VCC
10ns
0.5VCC
Standard output load
AC Electrical Specifications Over recommended operating conditions, unless otherwise specified.
100kHz
400kHz
SYMBOL
PARAMETER
MIN MAX
MIN
MAX
fSCL
tIN
tAA
tBUF
tLOW
tHIGH
tSU:STA
tHD:STA
tSU:DAT
tHD:DAT
tSU:STO
tDH
tR
SCL Clock Frequency
Pulse Width Suppression Time at Inputs
SCL LOW to SDA Data Out Valid
Time the Bus Free Before Start of New Transmission
Clock LOW Time
Clock HIGH Time
Start Condition Set-up Time
Start Condition Hold Time
Data in Setup Time
Data in Hold Time
Stop Condition Set-up Time
Data Output Hold Time
SDA and SCL Rise Time
0
100
0
400
n/a
n/a
50
0.1
0.9
0.1
0.9
4.7
1.3
4.7
1.3
4.0
0.6
4.7
0.6
4.0
0.6
250
100
5.0
0
0.6
0.6
50
50
1000 20 + 0.1Cb
300
(Note 5)
tF
SDA and SCL Fall Time
300
20 + 0.1Cb
300
(Note 5)
tSU:WP
tHD:WP
Cb
WP Set-up Time
WP Hold Time
Capacitive Load for Each Bus Line
0.4
0.6
0
0
400
400
NOTES:
4. Typical values are for TA = +25°C and VCC = 5.0V
5. Cb = total capacitance of one bus line in pF
UNIT
kHz
ns
µs
µs
µs
µs
µs
µs
ns
µs
µs
ns
ns
ns
µs
µs
pF
11
FN8113.2
June 30, 2008