SLH28 Datasheet, PDF (6/12 Pages) Interpoint Corporation Company – SLH Single and Dual DC-DC Converters | |||
|
◁ |
Crane Aerospace & Electronics Power Solutions
SLH Single and Dual DC-DC Converters
28 Volt input â 1.5 Watt
Tableâ7: Electrical Characteristics: -55° to +125°C case, 28 VDC Vin, 100% load, unless otherwise specified
Dual output models
PARAMETER
OUTPUT VOLTAGE 2
OUTPUT CURRENT 3
VIN = 16 to 40 V
OUTPUT POWER 3
VIN = 16 to 40 V
OUTPUT RIPPLE
10 kHz - 2 MHz ±VOUT
LINE REGULATION ±VOUT
LOAD REGULATION 4
10% - 100%
INPUT VOLTAGE
INPUT CURRENT
INPUT RIPPLE CURRENT 5
EFFICIENCY
LOAD FAULT 6
STEP LOAD RESPONSE
Balanced Loads
50% - 100% - 50% ±VOUT
STEP LINE RESPONSE 1
16 - 40 - 16 V, ±VOUT
START-UP 9
±VOUT
Capacitive Load 1
TC = 25°C, Each Output
CONDITIONS
±VOUT
Each Output
TOTAL
EAch Output
TOTAL
TC = 25°C
TC = -55°C TO +125°C
VIN = 16 TO 40 V
Balanced LoadS
±VOUT
CONTINUOUS
NO LOAD TO FULL
TRANSIENT 1 50 ms
NO LOAD
INHIBITED
10 kHz - 10 MHz
TC = 25°C
TC = -55°C TO +125°C
SHORT CIRCUIT
POWER DISSIPATION
RECOVERY 1
TRANSIENT 8
RECOVERY 1, 7
TRANSIENT 8
Recovery 7
DELAY
OVERSHOOT 1
No Effect on DC
Performance
SLH2805D
MIN TYP MAX
4.80 5.00 5.20
â
150 240
300
â
0.75 1.2
1.5
â
â
250
â
â
250
â
75
400
â
310 700
16
28
40
0
â
50
â
3.1
17
â
1.4
5
â
80
250
72
75
â
69
â
â
â
0.3
1.5
â
â
30
â ±150 ±400
â
â
600
â
â ±600
â
â
500
â
1
20
â
â
500
â
â
100
SLH2812D
MIN TYP MAX
11.52 12.00 12.48
â
62.5 100
125
â
0.75 1.2
1.5
â
â
400
â
â
400
â
75
700
SLH2815D
MIN TYP MAX
14.40 15.00 15.60
â
50
80
100
â
0.75 1.2
1.5
â
â
500
â
â
500
â
85
650
UNITS
V
mA
W
mV p-p
mV
â
350 700
â
370 700
mV
16
28
40
16
28
40
V
0
â
50
0
â
50
ms
â
3.1
17
â
3.3
17
mA
â
1.4
5
â
1.4
5
â
90
300
â
100 300 mA p-p
80
87
â
80
87
â
%
69
â
â
69
â
â
â
0.3
1.2
â
0.3
1.2
W
â
1
30
â
1
30
ms
â ±170 ±600 â ±200 ±700 mV pk
â
â
360
â
â
600
µs
â
â ±600 â
â ±600 mV pk
â
â
500
â
â
500
µs
â
2
20
â
2
20
ms
â
â
500
â
â
500 mV pk
â
â
100
â
â
100
µF
Notes
1. Guaranteed by characterization test and/or analysis. Not a production test.
2. Specified at 50%/50% balanced loads, one half of full load.
3. Maximum specification indicates 80% of the converterâs total current/power is
available from either output, provided the other output carries 20% of the total
power.
4. Although no minimum load is required, at no load the output voltage may exceed
rating by up to 15%.
5. An external 6 µH inductor, added in series to the input, is necessary to maintain
specifications.
6. Load fault is a short circuit into 1 . Recovery is into resistive full load.
7. Recovery is time for ±Vout to settle to within 1% of final value.
8. Transition time > 10 µs.
9. Measured from release of inhibit until Vout settles to within 1% of final value at
full load with Vin at 28 V.
www.craneae.com/interpoint
Page 6 of 12
SLH Rev AB - 2015.10.22
|
▷ |