SLH28 Datasheet, PDF (5/12 Pages) Interpoint Corporation Company – SLH Single and Dual DC-DC Converters | |||
|
◁ |
Crane Aerospace & Electronics Power Solutions
SLH Single and Dual DC-DC Converters
28 Volt input â 1.5 Watt
Tableâ6: Electrical Characteristics: -55° to +125°C case, 28 VDC Vin, 100% load, unless otherwise specified
single output models
PARAMETER
CONDITIONS
OUTPUT VOLTAGE 2
SLH2805S
MIN TYP MAX
4.80 5.00 5.20
SLH2812S
MIN TYP MAX
11.52 12.00 12.48
SLH2815S
MIN TYP MAX
14.40 15.00 15.60
UNITS
V
OUTPUT CURRENT
OUTPUT POWER
OUTPUT RIPPLE
10 kHz - 2 MHz
LINE REGULATION
LOAD REGULATION 3
Vin = 16 to 40 V
â
â
300
â
â
125
â
â
100
mA
Vin = 16 to 40 V
â
â
1.5
â
â
1.5
â
â
1.5
W
TC = 25°C
â
TC = -55°C TO +125°C â
65
150
â
â
250
â
35
200
â
â
300
â
60
200 mV p-p
â
300
Vin = 16 TO 40 V
â
115 300
â
60
400
â
60
650
mV
Load 10% to 100%
â
440 700
â
380 700
â
410 700
mV
INPUT VOLTAGE
NO LOAD TO FULL
Continuous
16
28
40
16
28
40
16
28
40
V
TRANSIENT 1 50 ms
â
â
50
â
â
50
â
â
50
V
INPUT CURRENT
NO LOAD
INHIBITED
â
2.9
17
â
2.3
17
â
2.4
17
mA
â
1.3
5
â
1.3
5
â
1.3
5
INPUT RIPPLE CURRENT 4 10 kHz - 10 MHz
â
85
250
â
75
300
â
60
300 mA p-p
EFFICIENCY
LOAD FAULT 5
STEP LOAD RESPONSE
TC = 25°C
72
79
â
80
87
â
80
88
â
%
TC = -55°C TO +125°C
69
â
â
69
â
â
69
â
â
SHORT CIRCUIT
POWER DISSIPATION
â
0.4
1.5
â
0.3
1.2
â
0.3
1.2
W
RECOVERY 1
â
â
30
â
â
30
â
â
30
ms
TRANSIENT 7
â ±250 ±400 â ±220 ±700 â ±220 ±700 mV pk
50% - 100% - 50%
STEP LINE RESPONSE 1
RECOVERY 1, 6
TRANSIENT 7
â
â
400
â
â
400
â
â
400
µs
â
â ±600 â
â ±600 â
â ±600 mV pk
16 - 40 - 16 V
START-UP 8
RECOVERY 6
DELAY
OVERSHOOT 1
â
â
500
â
â
500
â
â
500
µs
â
1
20
â
1
20
â
1
20
ms
â
â
100
â
â
500
â
â
500 mV pk
Capacitive Load 1
TC = 25°C, Each Output
No Effect on DC
Performance
â
â
100
â
â
100
â
â
100
µF
Notes:
1. Guaranteed by characterization test and/or analysis. Not a production test.
2. Specified at 50% load.
3. Although no minimum load is required, at no load the output voltage may exceed
rating by up to 15%.
4. An external 6 µH inductor, added in series to the input, is necessary to maintain
specifications.
5. Load fault is a short circuit into 1 . Recovery is into resistive full load.
6. Recovery is time to settle to within 1% of Vout final value.
7. Transition time > 10 µs.
8. Measured from release of inhibit until Vout settles to within 1% of final value at
full load with Vin at 28 V.
www.craneae.com/interpoint
Page 5 of 12
SLH Rev AB - 2015.10.22
|
▷ |