HR150 Datasheet, PDF (3/7 Pages) Interpoint Corporation Company – -40°C to +85°C operation Transient protection 50 V for 50 ms | |||
|
◁ |
DC/DC Converters
hr150
series
20 Watt
Electrical Characteristics: 25°C Tc, 28 VDC Vin, 100% load, unless otherwise specified.
dual output models
PARAMETER
CONDITIONS
output voltage
output current
output power
output ripple
0 to 1 MHz
input voltage
continuous
transient 50 ms
input current
no load
input ripple current
0 to 2 MHz
efficiency
hr152-2812
hr152-2815
MIN TYP MAX MIN TYP MAX
±11.88 ±12 ±12.12 ±14.85 ±15 ±15.15
â
â
±625 â
â
±500
â
â
15 â
â
15
â
30
50 â
30
50
18
28
36 18
28
36
â
â
50 â
â
50
â
â
35 â
â
35
â
25
50 â
25
50
75
79
â 75
79
â
UNITS
VDC
mA
W
mV p-p
VDC
V
mA
mA p-p
%
triple output models
PARAMETER
CONDITIONS
output voltage
output current
full
load
main
dual
main1
dual
output power
main
±dual
total
output ripple
0 to 1 MHz
main
dual
input voltage
continuous
transient 50 ms
input current
input ripple current
no load
0 to 2 MHz
efficiency
hr153-2812
hr153-2815
MIN TYP MAX MIN TYP MAX
4.95 5.00 5.05 4.95 5.00 5.05
±11.88 ±12 ±12.12 ±14.85 ±15 ±15.15
100 â 2000 100 â 2000
â
â
±208 â
â
±167
â
â
10 â
â
10
â
â
2.5 â
â
2.5
â
â
15 â
â
15
â
40
80 â
40
80
â
20
40 â
20
40
18
28
36 18
28
36
â
â
50 â
â
50
â
â
50 â
â
50
â
40
80 â
40
80
75
79
â 75
79
â
UNITS
VDC
mA
W
mV p-p
VDC
V
mA
mA p-p
%
Notes
1. Minimum load required for full output capability on auxiliary outputs. Minimum current can be reduced when dual outputs are used at reduced
loads.
www.interpoint.com
Page Â3ÂÂ of 7
HR150 Rev E 20100212
|
▷ |