English
Language : 

FMCE-0528 Datasheet, PDF (1/10 Pages) Interpoint Corporation Company – Attenuation to 60 dB at 500 kHz, typical Operating temperature -55° to +125°C
Crane Aerospace & Electronics Power Solutions
FMCE-0528 EMI Input Filters
28 Volt Input – 5 Amp
Features
Attenuation to 60 dB at 500 kHz, typical
• Operating temperature -55° to +125°C
• Nominal 28 V input,
-0.5 to 50 V operation with or without transorb
• Transient rating -0.5 to 80 V for 1 second
• Up to 5 A throughput current over the full input
voltage range -0.5 to 50 V
• Compliant to
-- MIL-STD-461C CE03
-- MIL-STD-461D, E and F CE102
-- MIL-STD-461C CS01
-- MIL-STD-461D, E, and F CS101
• Compatible with MIL-STD-704 A-E 28 VDC power bus
MODEL
FMCE-0528
FMCE-0528-TR
Input
Voltage (V)
28
28
Current
(A)
5
5
Description
The FMCE-0528™ EMI filters have been specifically designed to
reduce the input line reflected ripple current of Interpoint’s MTR,
MHF+, and MHV series of DC/DC converters. The filter can be
used with combinations of the lower power converters; up to two
MTR series converters or a single MFL series converter. These
filters are intended for use in 28 volt applications which must
meet MIL-STD-461C CE03 and CS01 and/or MIL-STD-461D, E
and F CE102 and CS101 levels of conducted emissions.
The FMCE-0528 filters are built using thick-film hybrid tech-
nology and are hermetically sealed in metal packages for military,
aerospace, and other high-reliability applications. Only ceramic
capacitors are used in the filters to ensure reliable high tempera-
ture operation.
The filters are offered with standard screening, “ES” screening,
or fully compliant to “883” MIL-PRF-38534 Class H screening.
Standard microcircuit drawings (SMD) are available.
MIL-STD Noise Management
When used in conjunction with Interpoint converters, the FMCE-
0528 and FMCE-0528-TR filters reduce input ripple current
within the frequency band of 100 kHz to 50 MHz. When used
with an Interpoint converter, performance exceeds the CEO3
test of MIL-STD-461C and meets the requirements of CS01 of
MIL-STD-461C. These filters also meet CE102 and CS101 of
MIL-STD-461D, E and F.
Transient Suppression - FMCE-0528-TR only
The FMCE-0528-TR filter also features an optional fast-reacting
(1 pico second) transient suppressor (transorb) which begins
clamping the input voltage at approximately 47 VDC, protecting
the DC/DC converter from damage from induced line transients.
The FMCE-0528 does not have the transorb and is designed for
those applications that require a wider input voltage range (0 to
50 V).
Operating Temperature
The filters are rated to operate, with no degradation of perfor-
mance, over the temperature range of -55°C to +125°C (as
measured at the baseplate). Above +125°C, current must be
derated as specified on the following page.
Insertion Loss
Low DC resistance design results in a maximum power loss of
less than 3% with typical input voltage.
Crane Aerospace & Electronics
Electronics Group (Interpoint Brand)
PO Box 97005•Redmond WA 98073-9705
425.882.3100 • power@crane-eg.com
www.interpoint.com
Page 1 of 10
FMCE-0528 Rev D - 20100413