English
Language : 

TLE4925 Datasheet, PDF (8/25 Pages) Infineon Technologies AG – Differential Hall Sensor
PRELIMINARY
2.1 Operating Range
No.
2.1.1
2.1.2
Parameter
Supply voltage
Symbol min
VS
3.3
3
Supply voltage ripple
VSAC
typ max Unit
Remarks
18
V Continuous
24
V 1h with RSeries ≥ 200Ω
26
V 5min with RSeries ≥
200Ω.
Extended limits for
parameters in
characteristics.
V During test pulse 4.
6
Vpp VS=13V; 0 < f < 50kHz
2.1.3 Continuous output OFF VQ
-0.3
voltage
-18
2.1.4 Continuous output ON
IQ
0
current
2.1.5
Power on time
ton
2.1.6
Operating junction
temperature
Tj
-40
18
V Continuous
24
V 1h with RLoad ≥ 500Ω
20
mA VQmax=0.6V
1
ms Time to achieve
specified accuracy
After power on the
output of the IC is
always in high-state.
After internal resets
output is locked3.
°C -
155 °C 2000 h (not additive)
165 °C 1000 h (not additive)
175 °C 168 h (not additive)
reduced signal
quality permittable
(e.g. jitter)
Note: Unless otherwise noted, all temperatures refer to junction temperature.
For the supply voltage lower than 28V (RSeries ≥ 200Ω) and junction temperature lower than 195°C
the magnetic and AC/DC characteristics can exceed the specification limits.
3 Output of the IC is locked in present state (high-state or low-state) after an internal reset is launched.
This reset happens typically every 780ms when there is no significant signal change. See also 2.2.14. A
voltage reset causes a release of the output and output is in high state after power on again.
Page 8 of 25