PLL Parameters
Parameter
Symbol
Limit Values1)
min.
max.
Accumulated jitter
VCO frequency range
PLL base frequency
DN
fVCO
fPLLBASE
see Figure 14
100
1502)
150
2003)
200
2504)
250
3005)
20
802)
20
1303)
20
1804)
20
2305)
PLL lock-in time
tL
–
1) Not subject to production test, verified by design/characterization.
2) @ vcosel = ’00’
3) @ vcosel = ’01’
4) @ vcosel = ’10’
5) @ vcosel = ’11’
200
Unit
–
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
µs
Note: When TC1910 starts-up with the PLL not bypassed, first user instructions are
executed with the frequency defined by the VCO free-running frequency
(fPLLBASE) and by the reset value of the PLL_CLC register (the K-divider and
VCOSEL bitfields). It is software responsibility to initialize its own appropriate
values in the bitfields in this register, before giving the command for the VCO to
lock to the input frequency. For more information, see the Users Manual, System
Units, System Control Unit chapter.