English
Language : 

V23815-U1306-MXXX Datasheet, PDF (4/9 Pages) Infineon Technologies AG – Parallel Optical Link: PAROLI T X AC, 1.6 Gbit/s
Pin#
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
Pin Name
VEE
VEE
DI02N
DI02P
VEE
VEE
DI03N
DI03P
VEE
VEE
t.b.l.o.
DI04N
DI04P
VEE
DI05N
DI05P
VEE
VEE
DI06N
DI06P
VEE
VEE
DI07N
DI07P
VEE
VEE
DI08N
DI08P
VEE
VEE
VEE
DI09N
DI09P
t.b.l.o.
VEE
VEE
DI10N
DI10P
VEE
VEE
DI11N
DI11P
57 VEE
58 VEE
59 DI12N
60 DI12P
Level/Logic Description
Ground
Ground
LVDS In
Data Input #2, inverted
LVDS In
Data Input #2, non- inverted
Ground
Ground
LVDS In
Data Input #3, inverted
LVDS In
Data Input #3, non- inverted
Ground
Ground
to be left open
LVDS In
Data Input #4, inverted
LVDS In
Data Input #4, non- inverted
Ground
LVDS In
Data Input #5, inverted
LVDS In
Data Input #5, non- inverted
Ground
Ground
LVDS In
Data Input #6, inverted
LVDS In
Data Input #6, non- inverted
Ground
Ground
LVDS In
Data Input #7, inverted
LVDS In
Data Input #7, non- inverted
Ground
Ground
LVDS In
Data Input #8, inverted
LVDS In
Data Input #8, non- inverted
Ground
Ground
Ground
LVDS In
Data Input #9, inverted
LVDS In
Data Input #9, non- inverted
to be left open
Ground
Ground
LVDS In
Data Input #10, inverted
LVDS In
Data Input #10, non- inverted
Ground
Ground
LVDS In
Data Input #11, inverted
LVDS In
Data Input #11,
non- inverted
Ground
Ground
LVDS In
Data Input #12, inverted
LVDS In
Data Input #12,
non- inverted
Pin#
61
62
63
64
Pin Name
VEE
VEE
t.b.l.o.
-RESET
65 VEE
66 VEE
67 LE
68 -LE
69 t.b.l.o.
70 t.b.l.o.
71 t.b.l.o.
72 VCC
Level/Logic Description
Ground
Ground
to be left open
LVCMOS In
High=laser diode array
is active
Low=switches laser diode
array off
This input has an internal
pull-down resistor to ensure
laser safety switch off in
case of unconnected
-RESET input
Ground
Ground
LVCMOS In
Laser ENABLE. High active.
High=laser array is on if -LE is
also active.
Low=laser array is off. This
input can be used for connec-
tion with an Open Fiber Con-
trol (OFC) circuit to enable
IEC class 1 links. Has an inter-
nal pull-up, therefore can be
left open.
Laser ENABLE. Low active.
Low=laser array is on if LE is
also active. This input can be
used for connection with an
Open Fiber Control (OFC) cir-
cuit to enable IEC class 1
links. Has an internal pull-
down, therefore can be left
open.
to be left open
to be left open
to be left open
Power supply voltage of
laser driver
Fiber Optics
V23814/15-U1306-M130 Parallel Optical Link: PAROLI™ Tx/Rx AC, 1.6 Gbit/s
4