TLE7242-2G Datasheet, PDF (39/50 Pages) Infineon Technologies AG – 4 Channel Fixed Frequency Constant Current Control IC
TLE7242-2G
Functional Description and Electrical Characteristics
Response:
On/Off Control and Fault Mask Configuration
Reset Value: 00 00 00 00H
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16
R/W
MSG_ID
0
0 CM0 CM1 CM2 CM3 FM0 FM1 FM2 FM3
15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
0
FMR FME DIAG_TMR AZ
0
0
0
0
0
0
0
0
0
0
0
Disable
Field
MSG_ID
CMx
FMx
FMR
Bits
30:26
Type
23, 22, 21,
20
19, 18, 17,
16
15
FME
14
DIAG_TMR 13:12
AZ Disable 11
Description
Message Identifier
0 0111 = On/Off Control and Fault Mask Configuration
Control Mode for Channel #x
0 = Current Control
1 = On/off
Fault Mask for Channel #x
0 = faults don’t trigger FAULT pin
1 = fault triggers FAULT pin
Fault Mask for RESET_B pin
0 = A low state on the ENABLE pin does not activate the FAULT pin.
1 = A low state on the ENABLE pin does activate the FAULT pin.
Note: when a high to low transition is detected on the ENABLE pin,
the ENABLE fault will be latched until the ENABLE pin returns high
AND a diagnostic read message is received.
Fault Mask for ENABLE pin
0 = A low state on the RESET_B pin does not activate the FAULT pin.
1 = A low state on the RESET_B pin does activate the FAULT pin.
Diagnostic Timer
00 = TIME_1 pre-divider = 128
01 = TIME_2 pre-divider = 192
10 = TIME_2 pre-divider = 192
11 = TIME_3 pre-divider = 256
Auto-Zero Disable
0 = Auto-Zero Enabled
1 = Auto-Zero Disabled
Data Sheet
39
Rev. 1.0, 2008-07-09