TLE4998C
SPC Output Definition
30µs after the master pulse crosses Vthr. tmd,tot is the delay between internal triggering
of the falling edge in the sensor and the triggering of the ECU.
Table 24 Master Pulse Parameters
Parameter
Symbol Limit Values Unit Notes
min. typ. max.
Falling edge threshold Vthf
1.1 1.3 1.7 V
Rising edge threshold Vthr
Total trigger time
tmtr
1.25 1.43 1.8 V
10.8 13 16.3 UT Synchronous mode 1)2)
46.6 56 70 UT Dyn. range mode 1)2)
75 90 113 UT ID selection mode 1)2)
Master delay time
tmd,tot 3.7 5.8 7.9 µs 3)
1) UT = Programmed nominal SPC unit time
2) Trigger time in the sensor is fixed to the number of unit times specified in the “typ.” column, but the effective
trigger time varies due to the sensor’s clock variation
3) For VDD = 5 V, RL = 2.2 kΩ, CL = 4.7 nF, ECU trigger level Vth,ECU = 2V
tmtr
OUT
Vthf,max
Vthf,min
Vthr,max
Vthr,min
tmlow,min
tmlow,max
Figure 14 SPC Master Pulse Timing
tmd,tot
ECU trigger
level
Data Sheet
38
Rev 1.0, 2008-12