2.4
Transfer Functions
The examples in Figure 4 show how different magnetic field ranges can be mapped to
the desired output value ranges.
• Polarity Mode:
– Bipolar: Magnetic fields can be measured in both orientations. The limit points
do not necessarily have to be symmetrical around the zero field point
– Unipolar: Only north- or south-oriented magnetic fields are measured
• Inversion: The gain can be set to both positive and negative values
B (mT)
50
OUT12 /
OUT16
B (mT)
4095 /
65535
100
OUT12 /
OUT16
B (mT)
4095 /
65535
200
OUT12 /
OUT16
4095 /
65535
0
0
0
0
0
0
-50
-100
Example 1:
- Bipolar
Example 2:
- Unipolar
- Big offset
Figure 4
Examples of Operation
-200
Example 3:
- Bipolar
- Inverted (neg. gain)
Data Sheet
11