English
Language : 

TLE4998C3 Datasheet, PDF (37/44 Pages) Infineon Technologies AG – Programmable Linear Hall Sensor
TLE4998C
SPC Output Definition
the application and should therefore be avoided, but in principle it is possible to adjust
the timer unit for a more precise protocol timing.
Table 23 Predivider Setting
Parameter
Symbol Limit Values
min. max.
Register size
Prediv
4
Unit time
tUNIT
2.0 3.88
1) Prediv default is decimal = 8 for 3 µs nominal SPC unit time
2) RC oscillator frequency variation +/- 20%
Unit
bit
µs
Notes
Predivider1)
ClkUNIT=8MHz2)
The nominal unit time is calculated by:
tUNIT = (Prediv + 16) / ClkUNIT
ClkUNIT = 8MHz ± 20%
13.3
Master Pulse Requirements
An SPC transmission is initiated by a Master pulse on the OUT pin. To detect a low level
on the OUT pin, the voltage must be below a threshold Vthf. The sensor detects that the
OUT line has been released as soon as Vthr is crossed. Figure 14 shows the timing
definitions for the master pulse. The master low time tmlow as well as the total trigger time
tmtr are individual for the different SPC modes and are given in the subsequent sections.
It is recommended to chose the typical master low time exactly between the minimum
and the maximum possible time: tmlow,typ = (tmlow,min + tmlow,max) / 2. Although the
allowed timing windows are larger for longer low times, the master should use a quarz
clock source to provide a high timing accuracy (approx. 1%). For improved robustness,
the master pulse can be adopted by the master once the effective unit time is known
through the sensor’s synchronisation period length. If the master low time exceeds the
maximum low time, the sensor does not respond and is available for a next triggering