English
Language : 

TLE4998C3 Datasheet, PDF (36/44 Pages) Infineon Technologies AG – Programmable Linear Hall Sensor
TLE4998C
SPC Output Definition
of 55 corresponds to 0°C. Table 22 shows the mapping between junction temperature
and the transmitted value in the SPC frame.
Table 22 Mapping of Temperature Value
Junction Temperature Typ. Decimal Value from Sensor Note
- 55°C
0
Theoretical lower limit1)
0°C
55
25°C
80
200°C
255
Theoretical upper limit1)
1) Theoretical range of temperature values, not operating temperature range
The status nibble allows to check internal states and conditions of the sensor.
• Depending on the selected SPC mode, the first two bits of the status nibble contain
either the selected magnetic range or the ID of the sensor and allow therefore an easy
interpretation of the received data.
• The third bit is set to “1” for the first transmission after the sensor returns from an
overvoltage operation with disabled open drain stage to regular operation (see
Chapter 7.1).
• The fourth bit is switched to “1” for the first data package transferred after a reset. This
allows the detection of low-voltage situations or EMC problems of the sensor.
13.2
Unit Time Setup
The basic SPC protocol unit time granularity is defined as 3 µs. Every timing is a multiple
of this basic time unit. To achieve more flexibility, trimming of the unit time can be used
to:
• Allow a calibration trim within a timing error of less than 20% clock error (as given in
SAE standard)
• Allow a modification of the unit time for small speed adjustments
This enables a setup of different unit times, even if the internal RC oscillator varies by
±20%. Of course, timing values that are too low could clash with timing requirements of
Data Sheet
36
Rev 1.0, 2008-12