C501 Datasheet, PDF (33/48 Pages) Siemens Semiconductor Group – 8-Bit CMOS Microcontroller
C501
AC Characteristics for C501-L / C501-1R / C501-1E
VCC = 5 V + 10 %, – 15 %; VSS = 0 V TA = 0 ˚C to 70 ˚C for the SAB-C501
TA = – 40 ˚C to 85 ˚C for the SAF-C501
(CL for port 0, ALE and PSEN outputs = 100 pF; CL for all other outputs = 80 pF)
Program Memory Characteristics
Parameter
ALE pulse width
Address setup to ALE
Address hold after ALE
ALE low to valid instr in
ALE to PSEN
PSEN pulse width
PSEN to valid instr in
Input instruction hold after PSEN
Input instruction float after PSEN
Address valid after PSEN
Address to valid instr in
Address float to PSEN
Symbol
Limit Values
Unit
12 MHz
Clock
min. max.
Variable Clock
1/tCLCL = 3.5 MHz to 12 MHz
min.
max.
tLHLL
tAVLL
tLLAX
tLLIV
tLLPL
tPLPH
tPLIV
tPXIX
t *)
PXIZ
t *)
PXAV
tAVIV
tAZPL
127 –
2tCLCL – 40
43 –
tCLCL – 40
30 –
tCLCL – 53
–
233 –
58 –
tCLCL – 25
215 –
3tCLCL – 35
–
150 –
0
–
0
–
63 –
75 –
tCLCL – 8
–
302 –
0
–
0
–
ns
–
ns
–
ns
4tCLCL – 100 ns
–
ns
–
ns
3tCLCL – 100 ns
–
ns
tCLCL – 20
ns
–
ns
5tCLCL – 115 ns
–
ns
*) Interfacing the C501 to devices with float times up to 75 ns is permissible. This limited bus contention will not
cause any damage to port 0 Drivers.
Semiconductor Group
33