3.5.1.3.1 TLE5012 Register
Status Register
TLE5012
Specification
STAT
Status Register
Offset
00H
Reset Value
8001H



5'B67
6B15
U
UZ



6B0$*2/ 6B;<2/
6B29
UX
UX
UX

12B*05B
$

12B*05B
;<
UX
UX


6B'638 6B)86(
UX
UX

6B520
U

6B95
UX

6B$'&7
UX

6B:'
UX

5HV

6B567
UX
Field
RD_ST
S_NR
NO_GMR_A
NO_GMR_XY
S_ROM
S_ADCT
Bits
15
14:13
12
11
10
9
Type
r
rw
ru
ru
r
ru
Description
Read Status
0B after readout
1B status values changed
Reset: 1B
Slave Number
is given at startup by the external circuit of IFA and IFB.
Reset: 00B
No GMR Angle Value
0B valid GMR angle value on the interface
1B no valid GMR angle value on the interface
Reset: 0B
No GMR XY Values
0B valid GMR_XY values on the interface
1B no valid GMR_XY values on the interface
Reset: 0B
Status ROM
0B after readout, CRC ok
1B CRC fail or running
Reset: 0B
Status ADC-Test
0B after readout
1B Test vectors out of limit
Reset: 0B
Target Data Sheet
31
V 0.46, 2009-09