English
Language : 

TLE7184F_15 Datasheet, PDF (28/38 Pages) Infineon Technologies AG – System IC for B6 motor drives
TLE7184F
Description of Modes, Protection and Diagnostic Functions
9.2.4 VS Under Voltage Lockout (VS_UVLO)
The TLE7184F has an integrated VS Under Voltage Lockout to assure that the behavior of the complete IC is
predictable in all supply voltage ranges.
If the supply voltage at VS reaches the Under Voltage shut down level VVSLO for a minimum specified filter time
the IC goes into Go-to-Sleep Mode and finally into Sleep Mode.
9.2.5 VDD Under Voltage Diagnosis (VDD_UVD)
The TLE7184F has an integrated VDD Under Voltage Diagnosis to assure that the behavior of the bridge driver
output stages is predictable in all supply voltage ranges.
If the voltage at VDD reaches the Under Voltage diagnosis level VUVVDD for a minimum specified filter time, an error
is set and the IC goes into Error Mode.
VS
VVDD
VRT
< TRR
TRR
ERR
____
RGS
Figure 11 Timing of VDD Under Voltage Diagnosis
9.2.6 VDD Under Voltage Shut Down (VDD_UVSD)
The TLE7184F has an integrated VDD Under Voltage Shut Down to avoid operation with VDD shorted to GND.
If the supply voltage at VDD reaches the Under Voltage shut down level VVDDsleep and the wake-up time is expired,
VREG and VDD will be switched off and the IC will go to Deadlock Mode.
9.2.7 VREG Under Voltage Diagnosis (VREG_UVD)
The TLE7184F has an integrated VREG Under Voltage Diagnosis to assure that the behavior of the bridge driver
output stages is predictable in all supply voltage ranges.
Data Sheet
28
Rev. 1.1, 2011-04-08