TLE4998P3C E1200
Temperature Compensation
2) Relative range to Infineon TC2 temperature pre-calibration, the maximum adjustable range is limited by the
register-size and depends on specific pre-calibrated TQ setting, full adjustable range: -15 to +15 ppm/°C2
3) Handled by algorithm only (see Application Note)
8.1
Parameter Calculation
The parameters TC1 and TC2 may be calculated by:
TC1
=
-T----L-----–----1---6---0-- × 1000000
65536
TC2
=
T-----Q------–----1---2---8-- × 1000000
8388608
The digital output for a given field BIN at a specific temperature can then be calculated
by:
DYOUT
=
2
⋅



--B-----I--N---
BFSR
×
STC
×
STCHall
×
S0
×

4096

+ DYOS
BFSR is the full range magnetic field. It is dependent on the range setting (e.g 100 mT).
S0 is the nominal sensitivity of the Hall probe times the Gain factor set in the EEPROM.
STC is the temperature-dependent sensitivity factor calculated by the DSP.
STCHall is the temperature behavior of the Hall probe.
The pre-calibration at Infineon is performed such that the following condition is met:
STC(TJ – T0) × STCHall(TJ) ≈ 1
Within the application, an additional factor BIN(T) / BIN(T0) will be given due to the
magnetic system. STC then needs to be modified to STCnew so that the following condition
is satisfied:
--B----I--N----(--T----)--
BIN(T0)
×
STCnew(T)
×
STCHall(T)
≈
STC(T)
×
STCHall(T)
≈
1
Therefore, the new sensitivity parameters STCnew can be calculated from the pre-
calibrated setup STC using the relationship:
--B----I--N----(--T----)--
BIN(T0)
×
STCnew(T)
≈
STC(T)
Data Sheet